CY325 ETC, CY325 Datasheet - Page 54

no-image

CY325

Manufacturer Part Number
CY325
Description
Stepper System Controller
Manufacturer
ETC
Datasheet
Each parameter has been assigned a potential range of 8 addresses, to make the address
decoding easier. Only the addresses shown are actually used to read digit values. The CY545
will not generate the unused address values.
Any parameter that will not be read from switches does not require the 74LS156 or switches for
that parameter. Any group of parameters that will not be read from switches does not require
the 74LS138 decoder either.
© 2002 Cybernetic Micro Systems
Group 1
Group 2
Group 3
Addresses
BCH - B8H
CAH - C8H
AAH - A8H
C2H - C0H
9CH - 98H
A2H - A0H
B2H - B0H
7CH - 78H
8FH - 88H
4AH - 48H
6AH - 68H
87H - 80H
97H - 90H
42H - 40H
52H - 50H
62H - 60H
72H - 70H
CY545 Thumbwheel Switch
Parameter Addresses
Parameter
N command number of steps
P command target position
A command at position
D command delay value
R command step rate
S command acceleration slope
F command first rate
Y command memory address
B command bit number
H command bit number
T command bit number
W command bit number
J command byte address
L command repeat count
Z command repeat count
O command mode value
? command query letter code
49
Chapter 13 - Thumbwheel Switch Support
8 digits
8 digits
8 digits
5 digits
3 digits
3 digits
3 digits
5 digits
3 digits
3 digits
3 digits
3 digits
3 digits
3 digits
5 digits
3 digits
3 digits
www.ControlChips.com