Bad Block Management
Devices with Bad Blocks have the same quality level and the same AC and DC characteristics as devices where all the
blocks are valid. A Bad Block does not affect the performance of valid blocks because it is isolated from the bit line and
common source line by a select transistor. The devices are supplied with all the locations inside valid blocks
erased(FFh).The Bad Block Information is written prior to shipping. Any block where the 6th Byte/ 1st Word in the
spare area of the 1st or 2nd page (if the 1st page is Bad) does not contain FFh is a Bad Block. The Bad Block Informa-
tion must be read before any erase is attempted as the Bad Block Information may be erased. For the system to be
able to recognize the Bad Blocks based on the original information it is recommended to create a Bad Block table fol-
lowing the flowchart shown in Figure 33. The 1st block, which is placed on 00h block address is guaranteed to be a
valid block.
www.DataSheet4U.com
Block Replacement
Over the lifetime of the device additional Bad Blocks may develop. In this case the block has to be replaced by copying
the data to a valid block. These additional Bad Blocks can be identified as attempts to program or erase them will give
errors in the Status Register.
As the failure of a page program operation does not affect the data in other pages in the same block, the block can be
replaced by re-programming the current data and copying the rest of the replaced block to an available valid block.The
Copy Back Program command can be used to copy the data to a valid block.
See the “Copy Back Program” section for more details.
Refer to Table 17 for the recommended procedure to follow if an error occurs during an operation.
Operation
Recommended Procedure
Erase
Block Replacement
Program
Block Replacement or ECC (with 1bit/512byte)
Read
ECC (with 1bit/512byte)
Table 17: Block Failure