TDA8029 Philips Semiconductors, TDA8029 Datasheet - Page 30

no-image

TDA8029

Manufacturer Part Number
TDA8029
Description
Low power single card reader
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA8029H/101
Manufacturer:
PHI
Quantity:
430
Part Number:
TDA8029H/C101
Manufacturer:
PHI
Quantity:
102
Part Number:
TDA8029H/C101
Manufacturer:
PHI
Quantity:
1 000
Part Number:
TDA8029H101
Manufacturer:
JRC
Quantity:
96
Part Number:
TDA8029H101
Manufacturer:
PHI
Quantity:
1 000
Part Number:
TDA8029H101
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
TDA8029HL/07
Manufacturer:
PHILIPS
Quantity:
1 977
Part Number:
TDA8029HL/07
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
TDA8029HL/C103
Manufacturer:
SGMICRO
Quantity:
2 988
Part Number:
TDA8029HL/C103
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
TDA8029HL/C104
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
TDA8029HL/C104
Quantity:
6 922
Part Number:
TDA8029HL/C206,118
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
TDA8029HL/C207
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
TDA8029HL/C207
0
Part Number:
TDA8029HL/C207,118
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
8.10.1.4
The time-out counter is very useful for processing the clock counting during ATR, the Work Waiting Time (WWT) or the
waiting times defined in protocol T = 1. It should be noted that the 200 and n
TDA8029HL/C1 and n
Specific hardware controls the functionality of BGT in T = 1 and T = 0 protocols and a specific register is available for
processing the extra guard time.
Writing to register TOC is not allowed as long as the card is not activated with a running clock.
Before restarting the 16-bit counter (counters 3 and 2) by writing 61h, 65h, 71h, 75h, F1h or F5h in the TOC register, or
the 24-bit counter (counters 3, 2 and 1) by writing 68h or 7C in the TOC register, it is mandatory to stop them by writing
00h in the TOC register.
Detailed examples of how to use these specific timers can be found in application note “AN01010” .
The time-out configuration register is used for setting different configurations of the time-out counter as given in Table 43,
all other configurations are undefined.
Table 42 Time-out configuration register, address 8h, read and write
Table 43 Time-out counter configurations
2003 Oct 30
Symbol
Reset value
00
05
61
65
68
71
TOC [7:0]
Low power single card reader
(HEX)
BIT
Time-Out Configuration register (TOC)
All counters are stopped.
Counters 2 and 3 are stopped; counter 1 continues to operate in auto-reload mode.
Counter 1 is stopped, and counters 3 and 2 form a 16-bit counter. Counting the value stored in registers
TOR3 and TOR2 is started after 61h is written in register TOC. When the terminal count is reached, an
interrupt is given, and bit TO3 in register USR is set. The counter is stopped by writing 00h in register
TOC, and should be stopped before reloading new values in registers TOR2 and TOR3.
Counter 1 is an 8-bit auto-reload counter, and counters 3 and 2 form a 16-bit counter. Counter 1 starts
counting the content of register TOR1 on the first start-bit (reception or transmission) detected on pin I/O
after 65h is written in register TOC. When counter 1 reaches its terminal count, an interrupt is given, bit
TO1 in register USR is set and the counter automatically restarts the same count until it is stopped. It is
not allowed to change the content of register TOR1 during a count. Counters 3 and 2 are wired as a
single 16-bit counter and start counting the value in registers TOR3 and TOR2 when 65h is written in
register TOC. When the counter reaches its terminal count, an interrupt is given and bit TO3 is set within
register USR. Both counters are stopped when 00h is written in register TOC. Counters 3 and 2 shall be
stopped by writing 05h in register TOC before reloading new values in registers TOR2 and TOR3.
Counters 3, 2 and 1 are wired as a single 24-bit counter. Counting the value stored in registers TOR3,
TOR2 and TOR1 is started after 68h is written in register TOC. The counter is stopped by writing 00h in
register TOC. It is not allowed to change the content of registers TOR3, TOR2 and TOR1 within a count.
Counter 1 is stopped, and counters 3 and 2 form a 16-bit counter. After writing this value, counting the
value stored in registers TOR3 and TOR2 is started on the first start-bit detected on pin I/O (reception or
transmission) and then on each subsequent start-bit. It is possible to change the content of registers
TOR3 and TOR2 during a count, the current count will not be affected and the new count value will be
taken into account at the next start-bit. The counter is stopped by writing 00h in register TOC. In this
configuration, registers TOR3, TOR2 and TOR1 must not be all zero.
TOC7
7
0
max
= 368 for TDA8029HL/C2) used during ATR is done by hardware when the start session is set.
TOC6
6
0
TOC5
5
0
OPERATING MODE
TOC4
30
4
0
TOC3
3
0
max
clock counter (n
TOC2
0
2
max
TOC1
Product specification
1
0
= 384 for
TDA8029
TOC0
0
0

Related parts for TDA8029