s29jl064j Meet Spansion Inc., s29jl064j Datasheet - Page 36

no-image

s29jl064j

Manufacturer Part Number
s29jl064j
Description
64 Megabit 8m X 8-bit/4m X 16-bit Cmos 3.0 Volt-only, Simultaneous Read/write Flash Memory
Manufacturer
Meet Spansion Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s29jl064j55TFI000
Manufacturer:
CYPRESS
Quantity:
1 000
Part Number:
s29jl064j55TFI000
0
Part Number:
s29jl064j60TFA003
Manufacturer:
CYPRESS
Quantity:
1 000
Part Number:
s29jl064j60TFI000
Manufacturer:
CYPRESS
Quantity:
1 000
Part Number:
s29jl064j60TFI003
Manufacturer:
CYPRESS
Quantity:
1 000
Part Number:
s29jl064j70BHI000
Manufacturer:
SPANSION
Quantity:
5
Part Number:
s29jl064j70TFI
Manufacturer:
SPANSION
Quantity:
20 000
Part Number:
s29jl064j70TFI00
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
s29jl064j70TFI000
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
s29jl064j70TFI000
Manufacturer:
SPANSION
Quantity:
1 000
Part Number:
s29jl064j70TFI000
Manufacturer:
SPANSION
Quantity:
20 000
Part Number:
s29jl064j70TFI000
0
Company:
Part Number:
s29jl064j70TFI000
Quantity:
20
Legend
X = Don’t care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WE# or CE# pulse, whichever happens later.
PD = Data to be programmed at location PA. Data latches on the rising edge of WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A21–A12 uniquely select any sector. Refer to
information on sector addresses.
BA = Address of the bank that is being switched to autoselect mode, is in bypass mode, or is being erased. A21–A19 uniquely select a bank.
Notes:
1. See
2. All values are in hexadecimal.
3. Except for the read cycle and the fourth, fifth, and sixth cycle of the autoselect command sequence, all bus cycles are write cycles.
4. Data bits DQ15–DQ8 are don’t care in command sequences, except for RD and PD.
5. Unless otherwise noted, address bits A21–A11 are don’t cares for unlock and command cycles, unless SA or PA is required.
6. No unlock or command cycles required when bank is reading array data.
7. The Reset command is required to return to the read mode (or to the erase-suspend-read mode if previously in Erase Suspend) when a bank is in the autoselect
8. The fourth cycle of the autoselect command sequence is a read cycle. The system must provide the bank address to obtain the manufacturer ID, device ID, or
9. The device ID must be read across the fourth, fifth, and sixth cycles.
10. The data is 81h for factory locked, 41h for customer locked, and 01h for not factory/customer locked.
36
Read
Reset
Enter Secured Silicon Region
Exit Secured Silicon Region
Program
Unlock Bypass
Unlock Bypass Program
Unlock Bypass Reset
Chip Erase
Sector Erase
Erase Suspend
Erase Resume
CFI Query
mode, or if DQ5 goes high (while the bank is providing status information).
Secured Silicon Region factory protect information. Data bits DQ15–DQ8 are don’t care. While reading the autoselect addresses, the bank address must be the
same until a reset command is given. See
Manufacturer ID
Device ID
Secured Silicon Region
Factory Protect
Boot Sector/Sector Block
Protect Verify
(Note 11)
(Note 6)
(Note 7)
Table 8.1 on page 14
(Note 16)
Command
Sequence
(Note 9)
(Note 1)
(Note 15)
(Note 14)
(Note 10)
(Note 13)
(Note 12)
for description of bus operations.
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
1
1
4
6
4
4
3
4
4
3
2
2
6
6
1
1
1
Autoselect Command Sequence on page 32
Addr
XXX
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
XXX
XXX
AAA
AAA
555
555
555
555
555
555
555
555
555
555
RA
BA
BA
AA
55
Table 10.1 S29JL064J Command Definitions
First
Data
RD
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
F0
A0
90
B0
30
98
Addr
XXX
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
555
555
555
555
555
555
555
555
555
555
PA
Second
Data
S29JL064J
PD
55
55
55
55
55
55
55
55
00
55
55
D a t a
(BA)AAA
(BA)AAA
(BA)AAA
(BA)AAA
(BA)555
(BA)555
(BA)555
(BA)555
Addr
AAA
AAA
AAA
AAA
AAA
AAA
555
555
555
555
555
555
Third
for more information.
Bus Cycles (Notes 2–5)
S h e e t
Data
88
90
A0
20
90
90
90
90
80
80
(BA)X00
(BA)X01
(BA)X02
(BA)X03
(BA)X06
(SA)X02
(SA)X04
Addr
XXX
AAA
AAA
555
555
PA
Fourth
81/41/
00/01
Data
PD
7E
AA
AA
01
01
00
S29JL064J_00_03 April 7, 2011
(BA)X1C
(BA)X0E
Addr
2AA
2AA
555
555
Fifth
Table 8.3 on page 20
Data
02
55
55
(BA)X1E
(BA)X0F
Addr
AAA
555
SA
Sixth
for
Data
01
10
30

Related parts for s29jl064j