max5961 Maxim Integrated Products, Inc., max5961 Datasheet - Page 9

no-image

max5961

Manufacturer Part Number
max5961
Description
0 To 16v, Quad, Hot-swap Controller With 10-bit Current And Voltage Monitor
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
max5961ETM+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
max5961ETM+T
Manufacturer:
MAXIM
Quantity:
356
PIN
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
1
2
3
4
5
6
7
8
9
SENSE1
SENSE3
FAULT1
FAULT2
FAULT3
FAULT4
GATE1
GATE3
ALERT
RETRY
NAME
DGND
MON1
MON3
GND1
GND3
DREG
ON1
ON3
ON4
ON2
POL
SDA
SCL
PG1
PG2
PG3
PG4
I.C.
_______________________________________________________________________________________
with 10-Bit Current and Voltage Monitor
Channel 1 Current-Sense Input. Connect SENSE1 to the source of an external MOSFET and to one end of
R
Channel 1 Voltage Monitoring Input
Channel 1 Gate-Drive Output. Connect to gate of an external n-channel MOSFET.
Channel 1 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.
Channel 3 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.
Channel 3 Gate-Drive Output. Connect to the gate of an external n-channel MOSFET.
Channel 3 Voltage Monitoring Input
Channel 3 Current-Sense Input. Connect SENSE3 to the source of an external MOSFET and to one end of
R
Polarity Select Input. Connect to DREG for active-high power-good outputs (PG_). Connect to GND_ for
active-low power-good outputs.
Logic Power-Supply Input. Connect to REG externally through a 10Ω resistor and to DGND with a 1µF
ceramic capacitor.
Channel 1 Precision Turn-On Input
Channel 3 Precision Turn-On Input
Channel 1 Active-Low Open-Drain Fault Output. FAULT1 goes low if an overcurrent shutdown occurs on
channel 1.
Channel 2 Active-Low Open-Drain Fault Output. FAULT2 goes low if an overcurrent shutdown occurs on
channel 2.
Channel 3 Active-Low Open-Drain Fault Output. FAULT3 goes low if an overcurrent shutdown occurs on
channel 3.
Channel 4 Active-Low Open-Drain Fault Output. FAULT4 goes low if an overcurrent shutdown occurs on
channel 4.
I
I
Open-Drain Alert Output. ALERT goes low during a fault to notify the system of an impending failure.
Channel 1 Open-Drain Power-Good Output
Channel 2 Open-Drain Power-Good Output
Channel 3 Open-Drain Power-Good Output
Channel 4 Open-Drain Power-Good Output
Digital Ground. Connect all GND_ and DGND to AGND externally using a star connection.
Channel 4 Precision Turn-On Input
Channel 2 Precision Turn-On Input
Autoretry Fault Management Input. Connect to DREG to enable autoretry operation. Connect to DGND to
enable latched-off operation.
Internally Connected. Connect to AGND only.
2
2
SENSE1
SENSE3
C Serial-Data Input/Output
C Serial-Clock Input
0 to 16V, Quad, Hot-Swap Controller
(see the Typical Application Circuit).
(see the Typical Application Circuit).
FUNCTION
Pin Description
9

Related parts for max5961