mc68hc908lj24 Freescale Semiconductor, Inc, mc68hc908lj24 Datasheet - Page 277

no-image

mc68hc908lj24

Manufacturer Part Number
mc68hc908lj24
Description
M68hc08 Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908LJ24
Manufacturer:
FREESCALE
Quantity:
3
Part Number:
mc68hc908lj24CFQ
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908lj24CFU
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908lj24CFU
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
mc68hc908lj24CPB
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
mc68hc908lj24CPB
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908lj24CPK
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908lj24CPK
Manufacturer:
FRE/MOT
Quantity:
20 000
MC68HC908LJ24/LK24 — Rev. 2.1
Freescale Semiconductor
Infrared Serial Communications Interface Module (IRSCI)
TC — Transmission Complete Bit
SCRF — SCI Receiver Full Bit
IDLE — Receiver Idle Bit
operation, clear the SCTE bit by reading SCS1 with SCTE set and
then writing to SCDR. Reset sets the SCTE bit.
This read-only bit is set when the SCTE bit is set, and no data,
preamble, or break character is being transmitted. TC generates an
SCI transmitter CPU interrupt request if the TCIE bit in SCC2 is also
set. TC is automatically cleared when data, preamble or break is
queued and ready to be sent. There may be up to 1.5 transmitter
clocks of latency between queueing data, preamble, and break and
the transmission actually starting. Reset sets the TC bit.
This clearable, read-only bit is set when the data in the receive shift
register transfers to the SCI data register. SCRF can generate an SCI
receiver CPU interrupt request. When the SCRIE bit in SCC2 is set,
SCRF generates a CPU interrupt request. In normal operation, clear
the SCRF bit by reading SCS1 with SCRF set and then reading the
SCDR. Reset clears SCRF.
This clearable, read-only bit is set when 10 or 11 consecutive logic 1s
appear on the receiver input. IDLE generates an SCI receiver CPU
interrupt request if the ILIE bit in SCC2 is also set. Clear the IDLE bit
by reading SCS1 with IDLE set and then reading the SCDR. After the
receiver is enabled, it must receive a valid character that sets the
SCRF bit before an idle condition can set the IDLE bit. Also, after the
IDLE bit has been cleared, a valid character must again set the SCRF
bit before an idle condition can set the IDLE bit. Reset clears the IDLE
bit.
1 = SCDR data transferred to transmit shift register
0 = SCDR data not transferred to transmit shift register
1 = No transmission in progress
0 = Transmission in progress
1 = Received data available in SCDR
0 = Data not available in SCDR
1 = Receiver input idle
0 = Receiver input active (or idle since the IDLE bit was cleared)
Infrared Serial Communications Interface Module (IRSCI)
I/O Registers
Data Sheet
277