agle600 Actel Corporation, agle600 Datasheet - Page 80

no-image

agle600

Manufacturer Part Number
agle600
Description
Iglooe Low-power Flash Fpgas With Flash*freeze Technology
Manufacturer
Actel Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
agle600V2-FG256
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
agle600V2-FG256I
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
agle600V2-FG484
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
agle600V2-FG484I
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
agle600V2-FGG256
Manufacturer:
Microsemi SoC
Quantity:
10 000
Part Number:
agle600V2-FGG484
Manufacturer:
Actel
Quantity:
135
IGLOOe DC and Switching Characteristics
Table 2-113 • Parameter Definition and Measuring Nodes
2 -6 8
Parameter Name
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
*
OCLKQ
OSUD
OHD
OSUE
OHE
OPRE2Q
OREMPRE
ORECPRE
OECLKQ
OESUD
OEHD
OESUE
OEHE
OEPRE2Q
OEREMPRE
OERECPRE
ICLKQ
ISUD
IHD
ISUE
IHE
IPRE2Q
IREMPRE
IRECPRE
See
Figure 2-26 on page 2-67
Clock-to-Q of the Output Data Register
Data Setup Time for the Output Data Register
Data Hold Time for the Output Data Register
Enable Setup Time for the Output Data Register
Enable Hold Time for the Output Data Register
Asynchronous Preset-to-Q of the Output Data Register
Asynchronous Preset Removal Time for the Output Data Register
Asynchronous Preset Recovery Time for the Output Data Register
Clock-to-Q of the Output Enable Register
Data Setup Time for the Output Enable Register
Data Hold Time for the Output Enable Register
Enable Setup Time for the Output Enable Register
Enable Hold Time for the Output Enable Register
Asynchronous Preset-to-Q of the Output Enable Register
Asynchronous Preset Removal Time for the Output Enable Register
Asynchronous Preset Recovery Time for the Output Enable Register
Clock-to-Q of the Input Data Register
Data Setup Time for the Input Data Register
Data Hold Time for the Input Data Register
Enable Setup Time for the Input Data Register
Enable Hold Time for the Input Data Register
Asynchronous Preset-to-Q of the Input Data Register
Asynchronous Preset Removal Time for the Input Data Register
Asynchronous Preset Recovery Time for the Input Data Register
for more information.
Parameter Definition
A d v a n c e v 0. 3
Measuring Nodes
(from, to)*
H, DOUT
H, EOUT
L, DOUT
I, EOUT
G, H
G, H
K, H
D, A
D, A
K, H
A, E
C, A
C, A
B, A
B, A
D, E
L, H
L, H
J, H
J, H
F, H
F, H
I, H
I, H

Related parts for agle600