cx29610 Mindspeed Technologies, cx29610 Datasheet - Page 52

no-image

cx29610

Manufacturer Part Number
cx29610
Description
Optiphytm - M622 Sts-12/4x Sts-3 Sonet/sdh Multiplexer
Manufacturer
Mindspeed Technologies
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
cx29610-12
Manufacturer:
MINDSPEED
Quantity:
20 000
2.0 Functional Description
2.2 Clock Circuits
Table 2-3. Transmit/Receive Default Clock Configuration
2-8
SONET STS-12
Internal CDR enabled
Transmit clock synthesized from 19.44 MHz
reference input (LTxSynRef pin)
LTxData sourced from transmit framer
Receive data from LRxData +/- inputs
PECL line loopback disabled
Local source loopback disabled
LTxData buffer enabled
LTxClk buffer power down enabled
CDR charge pump frequency - 622 MHz
Transmit clock synthesizer enabled
CDR PLL hysteresis values
Configuration Description
selections for loopback capabilies. The available loopback modes are described in
Section
of the the line interface for the OC-12 SONET mode. This is the default mode of
operation upon device reset. The control registers shown in
The line interface circuits of the CX29610 provide many clock and data path
Table 2-3
2.8.
Mindspeed Technologies
GEN[7]
CLKREC[5]
CLKREC[4:3]
CLKREC[2]
CLKREC[1]
CLKREC[0]
CLKRECPD[6]
CLKRECPD[4]
CLKRECPD[3]
TESTMODE[7]
TESTMODE[6]
WINHYST1_L
shows the register bits which are required for proper configuration
Control Register and
Bit Position Index
WINHYST
PrtMode = 1
ExtClkRec = 0
TxClkSel[1:0] = 00
TxDataSel = 0
SrcLoop = 0
NELnLoop = 0
LclSrcLoop = 0
PD_Data = 0
PD_Clk = 1
Speed_CP = 1
Pd_TxSyn = 0
Register Bit Names
and Values
Figures 2-5
GEN = 0x80
CLKREC = 0x00
CLKRECPD = 0x08
TESTMODE = 0x80
CX29610 Data Sheet
Default Register
29610-DSH-001-C
Value
and 2-6.
CX29610

Related parts for cx29610