hy5du561622ct Hynix Semiconductor, hy5du561622ct Datasheet - Page 12

no-image

hy5du561622ct

Manufacturer Part Number
hy5du561622ct
Description
256m 16mx16 Gddr Sdram
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
hy5du561622ct-28
Quantity:
400
Company:
Part Number:
hy5du561622ct-28
Quantity:
400
Part Number:
hy5du561622ct-33
Manufacturer:
HYNIX
Quantity:
298
Part Number:
hy5du561622ct-33
Manufacturer:
HYNIX
Quantity:
10 685
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 100
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 100
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 250
Part Number:
hy5du561622ct-4
Manufacturer:
HYNIX
Quantity:
17
Part Number:
hy5du561622ctP-4
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Part Number:
hy5du561622ctP-D43
Manufacturer:
HY
Quantity:
1 000
Part Number:
hy5du561622ctP-D43
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Rev. 1.3 / Feb. 2006
OPERATION COMMAND TRUTH TABLE - IV
Note :
1. H - Logic High Level, L - Logic Low Level, X - Don’t Care, V - Valid Data Input,
2. All entries assume that CKE was active(high level) during the preceding clock cycle.
3. If both banks are idle and CKE is inactive(low level), then in power down mode.
4. Illegal to bank in specified state. Function may be legal in the bank indicated by Bank Address(BA) depending on the state of
5. If both banks are idle and CKE is inactive(low level), then self refresh mode.
6. Illegal if tRCD is not met.
7. Illegal if tRAS is not met.
8. Must satisfy bus contention, bus turn around, and/or write recovery requirements.
9. Illegal if tRRD is not met.
10. Illegal for single bank, but legal for other banks in multi-bank devices.
11. Illegal for all banks.
ACCESSING
BA - Bank Address, AP - AutoPrecharge Address, CA - Column Address, RA - Row Address, NOP - NO Operation.
that bank.
REGISTER
Current
WRITE
State
MODE
/CS
H
L
L
L
L
L
L
L
L
L
L
L
L
L
/RAS
H
H
H
H
H
L
L
L
L
X
L
L
L
L
/CAS
H
H
H
H
H
H
L
L
L
X
L
L
L
L
/WE
H
H
H
H
H
H
X
L
L
L
L
L
L
L
BA, CA, AP
BA, CA, AP
BA, CA, AP
Address
OPCODE
OPCODE
BA, RA
BA, RA
BA, AP
BA, AP
X
X
X
X
X
WRITE/WRITEAP
WRITE/WRITEAP
READ/READAP
Command
AREF/SREF
AREF/SREF
PRE/PALL
PRE/PALL
DSEL
MRS
NOP
MRS
ACT
ACT
BST
NOP - Enter IDLE after tMRD
NOP - Enter IDLE after tMRD
1HY5DU561622CT
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
Action
11
11
11
11
11
11
11
11
11
11
11
11
12