hy5du561622ct Hynix Semiconductor, hy5du561622ct Datasheet - Page 7

no-image

hy5du561622ct

Manufacturer Part Number
hy5du561622ct
Description
256m 16mx16 Gddr Sdram
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
hy5du561622ct-28
Quantity:
400
Company:
Part Number:
hy5du561622ct-28
Quantity:
400
Part Number:
hy5du561622ct-33
Manufacturer:
HYNIX
Quantity:
298
Part Number:
hy5du561622ct-33
Manufacturer:
HYNIX
Quantity:
10 685
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 100
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 100
Part Number:
hy5du561622ct-36
Manufacturer:
HY
Quantity:
6 250
Part Number:
hy5du561622ct-4
Manufacturer:
HYNIX
Quantity:
17
Part Number:
hy5du561622ctP-4
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Part Number:
hy5du561622ctP-D43
Manufacturer:
HY
Quantity:
1 000
Part Number:
hy5du561622ctP-D43
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Rev. 1.3 / Feb. 2006
SIMPLIFIED COMMAND TRUTH TABLE
Note :
1. LDM/UDM states are Don’t Care. Refer to below Write Mask Truth Table.
2. OP Code(Operand Code) consists of A0~A12 and BA0~BA1 used for Mode Register setting during Extended MRS or MRS.
3. If a Read with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented
4. If a Write with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented
5. If A10/AP is High when Precharge command being issued, BA0/BA1 are ignored and all banks are selected to be
Precharge Power
Extended Mode Register Set
(tWR) is needed to guarantee that the last data has been completely written.
Before entering Mode Register Set mode, all banks must be in a precharge state and MRS command can be issued after tRP
period from Prechagre command.
to activated bank until CK(n+BL/2+tRP).
to activated bank until CK(n+BL/2+1+tDPL+tRP). Last Data-In to Prechage delay(tDPL) which is also called Write Recovery Time
precharged.
Write with Autoprecharge
Read with Autoprecharge
Active Power
Precharge selected Bank
Self Refresh
Down Mode
Down Mode
Precharge All Banks
Mode Register Set
( H=Logic High Level, L=Logic Low Level, X=Don’t Care, V=Valid Data Input, OP Code=Operand Code, NOP=No Operation )
Read Burst Stop
Device Deselect
No Operation
Auto Refresh
Command
Bank Active
Write
Read
Entry
Entry
Entry
Exit
Exit
Exit
CKEn-1
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
CKEn
H
H
H
H
X
X
X
X
X
X
X
X
L
L
L
CS
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
RAS
H
H
H
H
H
H
H
L
L
X
L
L
L
L
X
X
X
X
V
X
CAS
X
H
H
H
H
X
H
X
H
X
H
X
V
L
L
L
L
L
L
WE
H
H
H
H
H
H
H
H
X
X
X
X
X
V
L
L
L
L
L
ADDR
CA
CA
X
1HY5DU561622CT
RA
OP code
OP code
A10/
AP
X
H
H
H
X
X
X
X
X
L
L
L
BA
V
V
V
X
V
Note
1,2
1,2
1,3
1,4
1,5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7

Related parts for hy5du561622ct