SC16C650BIBS PHILIPS [NXP Semiconductors], SC16C650BIBS Datasheet - Page 27

no-image

SC16C650BIBS

Manufacturer Part Number
SC16C650BIBS
Description
5 V, 3.3 V and 2.5 V UART with 32-byte FIFOs and infrared (IrDA) encoder/decoder
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet
Philips Semiconductors
9397 750 14451
Product data
7.7 Line Status Register (LSR)
This register provides the status of data transfers between the SC16C650B and
the CPU.
Table 20:
Bit
7
6
5
4
3
2
1
Symbol
LSR[7]
LSR[6]
LSR[5]
LSR[4]
LSR[3]
LSR[2]
LSR[1]
Line Status Register bits description
Rev. 03 — 10 December 2004
Description
FIFO data error.
THR and TSR empty. This bit is the Transmit Empty indicator. This bit is
set to a logic 1 whenever the transmit holding register and the transmit
shift register are both empty. It is reset to logic 0 whenever either the THR
or TSR contains a data character. In the FIFO mode, this bit is set to ‘1’
whenever the transmit FIFO and transmit shift register are both empty.
THR empty. This bit is the Transmit Holding Register Empty indicator.
This bit indicates that the UART is ready to accept a new character for
transmission. In addition, this bit causes the UART to issue an interrupt to
CPU when the THR interrupt enable is set. The THR bit is set to a logic 1
when a character is transferred from the transmit holding register into the
transmitter shift register. The bit is reset to a logic 0 concurrently with the
loading of the transmitter holding register by the CPU. In the FIFO mode,
this bit is set when the transmit FIFO is empty; it is cleared when at least
1 byte is written to the transmit FIFO.
Break interrupt.
Framing error.
Parity error.
Overrun error.
Logic 0 = No error (normal default condition).
Logic 1 = At least one parity error, framing error or break indication is in
the current FIFO data. This bit is cleared when LSR register is read.
Logic 0 = No break condition (normal default condition).
Logic 1 = The receiver received a break signal (RX was a logic 0 for
one character frame time). In the FIFO mode, only one break character
is loaded into the FIFO.
Logic 0 = No framing error (normal default condition).
Logic 1 = Framing error. The receive character did not have a valid stop
bit(s). In the FIFO mode, this error is associated with the character at
the top of the FIFO.
Logic 0 = No parity error (normal default condition).
Logic 1 = Parity error. The receive character does not have correct
parity information and is suspect. In the FIFO mode, this error is
associated with the character at the top of the FIFO.
Logic 0 = No overrun error (normal default condition).
Logic 1 = Overrun error. A data overrun error occurred in the receive
shift register. This happens when additional data arrives while the FIFO
is full. In this case, the previous data in the shift register is overwritten.
Note that under this condition, the data byte in the receive shift register
is not transferred into the FIFO, therefore the data in the FIFO is not
corrupted by the error.
UART with 32-byte FIFOs and IrDA encoder/decoder
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
SC16C650B
27 of 51