SAA7124WP PHILIPS [NXP Semiconductors], SAA7124WP Datasheet - Page 18

no-image

SAA7124WP

Manufacturer Part Number
SAA7124WP
Description
Digital Video Encoder ECO-DENC
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet
Philips Semiconductors
I
Table 4 I
Table 5 Explanation of Table 4
Notes
1. X is the read/write control bit; X = logic 0 is order to write; X = logic 1 is order to read, no subaddressing with read.
2. If more than 1 byte DATA is transmitted, then auto-increment of the subaddress is performed.
Slave Receiver
Table 6 Subaddress 3A
1996 Nov 07
2
S
Slave address
ACK
Subaddress (note 2)
DATA
--------
P
UV2C
Y2C
DEMOFF
SYMP
YC_EN
CBENB
C-bus format
Digital Video Encoder (ECO-DENC)
DATA
BYTE
S
SLAVE ADDRESS
2
PART
C-bus address; see Table 5
LOGIC
LEVEL
0
1
0
1
0
1
0
1
0
1
0
1
Cb, Cr data are two’s complement.
Cb, Cr data are straight binary. Default after reset.
Y data is two’s complement.
Y data is straight binary. Default after reset.
Y, Cb and Cr for RGB dematrix is active. Default after reset.
Y, Cb and Cr for RGB dematrix is bypassed.
Horizontal and vertical trigger is taken from RCV2 and RCV1 respectively. Default after reset.
Horizontal and vertical trigger is decoded out of “CCIR 656” compatible data at MP port.
Output of CVBS and RGB signals. Default after reset.
Output of Y, C, and CVBS, CVBS signals.
Data from input ports is encoded. Default after reset.
Colour bar with fixed colours is encoded. The LUTs are read in upward order from
index 0 to index 7.
START condition
1 0 0 0 1 0 0 X or 1 0 0 0 1 1 0 X (note 1)
acknowledge, generated by the slave
subaddress byte
data byte
continued data bytes and ACKs
STOP condition
ACK
SUBADDRESS
ACK
18
DESCRIPTION
DATA 0
DESCRIPTION
ACK
--------
SAA7124; SAA7125
Preliminary specification
DATA n
ACK
P