PEB2085 SIEMENS [Siemens Semiconductor Group], PEB2085 Datasheet - Page 109

no-image

PEB2085

Manufacturer Part Number
PEB2085
Description
ISDN SubscribernAccess Controller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2085-P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
ALLEGRO
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
LNFINEON
Quantity:
20 000
Part Number:
PEB2085N V2.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB2085NV1.1
Manufacturer:
PHI
Quantity:
399
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS
Quantity:
5 967
Part Number:
PEB2085NV2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085P
Quantity:
41
Part Number:
PEB2085P
Manufacturer:
SIEMENS
Quantity:
1 000
Only the logical connection identified through the address combination SAP1, TEI1 will be
processed in the auto mode, all others are handled as in the non-auto mode. The logical
connection handled in the auto mode must have a window size 1 between transmitted and
acknowledged frames. HDLC frames with address fields that do not match with any of the
address combinations, are ignored by the ISAC-S.
In case of a 1-byte address, TEI1 and TEI2 will be used as compare registers. According to
the X.25 LAPB protocol, the value in TEI1 will be interpreted as command and the value in
TEI2 as response.
The control field is stored in the RHCR register and the I field in the RFIFO. Additional
information is available in the RSTA.
Non-auto mode (MDS2, MDS1 = 01)
Characteristics:
All frames with valid addresses (address recognition identical to auto mode) are accepted and
the bytes following the address are transferred to the P via RHCR and RFIFO. Additional
information is available in the RSTA.
Transparent mode 1 (MDS2, MDS1, MDS0 = 101)
Characteristics:
A comparison is performed only on the second byte after the opening flag, with TEI1, TEI2 and
group TEI (FF
of the) control field in RHCR, and the rest of the frame in the RFIFO. Additional information is
available in the RSTA.
Transparent mode 2 (MDS2, MDS1, MDS0 = 110)
Characteristics:
Every received frame is stored in the RFIFO (first byte after opening flag to CRC field).
Additional information can be read from the RSTA.
Transparent mode 3 (MDS2, MDS1, MDS0 = 111)
Characteristics:
A comparison is performed on the first byte after the opening flag with SAP1, SAP2 and group
SAPI (FE/FC
information can be read from the RSTA.
2.8.2
In addition to address recognition all S and I frames are processed in hardware in the auto
mode. The following functions are performed:
– update of transmit and receive counter
– evaluation of transmit and receive counter
Semiconductor Group
Protocol Operations (auto mode)
H
H
). In the case of a match, all the following bytes are stored in RFIFO. Additional
). In the case of a match, the first address byte is stored in SAPR, the (first byte
Full address recognition (1 or 2 bytes)
Arbitrary window sizes
TEI recognition
no address recognition
SAPI recognition
109
Functional Description

Related parts for PEB2085