PEB2085 SIEMENS [Siemens Semiconductor Group], PEB2085 Datasheet - Page 113

no-image

PEB2085

Manufacturer Part Number
PEB2085
Description
ISDN SubscribernAccess Controller
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2085-P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
ALLEGRO
Quantity:
5 510
Part Number:
PEB2085N
Manufacturer:
LNFINEON
Quantity:
20 000
Part Number:
PEB2085N V2.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB2085NV1.1
Manufacturer:
PHI
Quantity:
399
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV1.1
Manufacturer:
SIE
Quantity:
20 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS
Quantity:
5 967
Part Number:
PEB2085NV2.3
Manufacturer:
SIE
Quantity:
1 000
Part Number:
PEB2085NV2.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2085P
Quantity:
41
Part Number:
PEB2085P
Manufacturer:
SIEMENS
Quantity:
1 000
When 32 bytes of a message longer than that are stored in the RFIFO, the CPU is prompted
to read out the data by an RPF interrupt. The CPU must handle this interrupt before more than
32 additional bytes are received, which would cause a "data overflow" (figure 59).This
corresponds to a maximum CPU reaction time of 16 ms (data rate 16 kbit/s).
After a remaining block of less than or equal to 16 bytes has been stored, it is possible to store
the first 16 bytes of a new message (see figure 59).
The internal memory is now full. The arrival of additional bytes will result in "data overflow"
(RSTA:RDO) and a third new message in "frame overflow" (EXIR:RFO).
The generated interrupts are inserted together with all additional information into a queue to
be individually passed to the CPU.
After an RPF or RME interrupt has been processed, i.e. the received data has been read from
the RFIFO, this must be explicitly acknowledged by the CPU issuing an RMC (Receive
Message Complete) command.
The ISAC-S can then release the associated FIFO pool for new data. If there is an additional
interrupt in the queue it will be generated after the RMC acknowledgement.
Figure 59
Contents of the RFIFO (long messages)
Semiconductor Group
31
31
0
0
the Queue
Long
Message
RFIFO
Interrupts in
RPF
RPF
113
15
16
31
31
0
0
Long
Message
< (
Message 2
< (
_
_
46
32
RFIFO
bytes)
bytes)
1
Functional Description
Interrupts in
the Queue
ITS01501
RPF
RME
RME

Related parts for PEB2085