8-bit Microcontroller with 16K Bytes In-System Programmable Flash
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATMEGA169-16AI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA169-16AI SL709
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA169-16AI SL710
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA169-16AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA169A-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATMEGA169P-15AT
Manufacturer:
PANASONIC
Quantity:
301
Part Number:
ATMEGA169P-15AT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA169P-16AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA169PA-MU
Manufacturer:
ATMEL
Quantity:
31
Part Number:
ATMEGA169PAAU
Manufacturer:
INF
Quantity:
4 275
Timer/Counter1 Interrupt Flag
Register – TIFR1
2514P–AVR–07/06
• Bit 5 – ICF1: Timer/Counter1, Input Capture Flag
This flag is set when a capture event occurs on the ICP1 pin. When the Input Capture
Register (ICR1) is set by the WGM13:0 to be used as the TOP value, the ICF1 Flag is
set when the counter reaches the TOP value.
ICF1 is automatically cleared when the Input Capture Interrupt Vector is executed. Alter-
natively, ICF1 can be cleared by writing a logic one to its bit location.
• Bit 2 – OCF1B: Timer/Counter1, Output Compare B Match Flag
This flag is set in the timer clock cycle after the counter (TCNT1) value matches the Out-
put Compare Register B (OCR1B).
Note that a Forced Output Compare (FOC1B) strobe will not set the OCF1B Flag.
OCF1B is automatically cleared when the Output Compare Match B Interrupt Vector is
executed. Alternatively, OCF1B can be cleared by writing a logic one to its bit location.
• Bit 1 – OCF1A: Timer/Counter1, Output Compare A Match Flag
This flag is set in the timer clock cycle after the counter (TCNT1) value matches the Out-
put Compare Register A (OCR1A).
Note that a Forced Output Compare (FOC1A) strobe will not set the OCF1A Flag.
OCF1A is automatically cleared when the Output Compare Match A Interrupt Vector is
executed. Alternatively, OCF1A can be cleared by writing a logic one to its bit location.
• Bit 0 – TOV1: Timer/Counter1, Overflow Flag
The setting of this flag is dependent of the WGM13:0 bits setting. In Normal and CTC
modes, the TOV1 Flag is set when the timer overflows. Refer to Table 58 on page 119
for the TOV1 Flag behavior when using another WGM13:0 bit setting.
TOV1 is automatically cleared when the Timer/Counter1 Overflow Interrupt Vector is
executed. Alternatively, TOV1 can be cleared by writing a logic one to its bit location.
Bit
Read/Write
Initial Value
R
7
0
R
6
0
ICF1
R/W
5
0
R
4
0
3
R
0
OCF1B
R/W
2
0
ATmega169/V
OCF1A
R/W
1
0
TOV1
R/W
0
0
TIFR1