M30622 Mitsubishi, M30622 Datasheet - Page 89

no-image

M30622

Manufacturer Part Number
M30622
Description
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Manufacturer
Mitsubishi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M30622-109GP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M30622ECFP
Manufacturer:
INFINEON
Quantity:
607
Part Number:
M30622ECFP
Manufacturer:
ST
0
Part Number:
M30622EECFP
Manufacturer:
MIT
Quantity:
20 000
Part Number:
M30622F8PA04GP
Manufacturer:
MIT
Quantity:
105
Part Number:
M30622F8PA04GP
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
M30622F8PA04GP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M30622F8PFP
Manufacturer:
MIT
Quantity:
20 000
Part Number:
M30622F8PFP#D5C
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30622F8PFP#U3C
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30622F8PFP#U5C
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30622F8PFPD5
Manufacturer:
RENESAS
Quantity:
893
Part Number:
M30622F8PFPU3C
Manufacturer:
RENESAS
Quantity:
5 002
Part Number:
M30622F8PFPU5U
Manufacturer:
STM
Quantity:
4 667
Part Number:
M30622F8PGP
Manufacturer:
MIT
Quantity:
20 000
Timer A
Table 1.17.3. Timer specifications in event counter mode (when processing two-phase pulse signal with timers A2, A3, and A4)
Note 1: This does not apply when the free-run function is selected.
Note 2: M30623(80-pin package) does not have I/O pins(TAi
Count source
Count operation
Divide ratio
Count start condition
Count stop condition
Interrupt request generation timing
TAi
TAi
Read from timer
Write to timer
Select function
IN
OUT
Tentative Specifications REV.A
pin function
pin function
S
Item
pecifications in this manual are tentative and subject to change.
• Two-phase pulse signals input to TAi
• Up count or down count can be selected by two-phase pulse signal
• When the timer overflows or underflows, the reload register content is
1/ (FFFF
1/ (n + 1) for down count
Count start flag is set (= 1)
Count start flag is reset (= 0)
Timer overflows or underflows
Two-phase pulse input
Two-phase pulse input
Count value can be read out by reading timer A2, A3, or A4 register
• When counting stopped
• When counting in progress
• Normal processing operation
• Multiply-by-4 processing operation
reloaded and the timer starts over again (Note)
When a value is written to timer A2, A3, or A4 register, it is written to both
reload register and counter
When a value is written to timer A2, A3, or A4 register, it is written to only
reload register. (Transferred to counter at next reload time.)
The timer counts up rising edges or counts down falling edges on the TAi
pin when input signal on the TAi
If the phase relationship is such that the TAi
signal on the TAi
on the TAi
TAi
counts down rising and falling edges on the TAi
TAi
TAi
TAi
TAi
IN
(i=2,3)
OUT
OUT
IN
(i=3,4)
IN
pin goes “L” when the input signal on the TAi
16
- n + 1) for up count
OUT
Count up all edges
Count up all edges
Up
count
and TAi
OUT
pin is “H”, the timer counts up rising and falling edges
89
Up
count
IN
pins. If the phase relationship is such that the
Specification
IN
Up
count
OUT
,TAi
n : Set value
OUT
pin is “H”
IN
Down
count
Count down all edges
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Count down all edges
or TAi
) for timer A1 and A2.
IN
OUT
Down
count
pin goes “H” when the input
OUT
pin
OUT
and TAi
Mitsubishi microcomputers
Down
count
pin is “H”, the timer
M16C / 62T Group
IN
pins.
IN

Related parts for M30622