UPD62A NEC, UPD62A Datasheet - Page 23

no-image

UPD62A

Manufacturer Part Number
UPD62A
Description
4-BIT SINGLE-CHIP MICROCONTROLLER FOR INFRARED REMOTE CONTROL TRANSMISSION
Manufacturer
NEC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD62AGS-798
Manufacturer:
NEC
Quantity:
1 697
Part Number:
UPD62AGS-798
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD62AGS-798
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD62AMC
Manufacturer:
SANYO
Quantity:
3 500
Part Number:
UPD62AMC-707-5A4-E1
Manufacturer:
NEC
Quantity:
2 500
Part Number:
UPD62AMC-707-5A4-E1
Manufacturer:
NEC
Quantity:
2 500
Part Number:
UPD62AMC-707-5A4-E1
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD62AMC-710-5A4-E2
Manufacturer:
NEC
Quantity:
37 500
Part Number:
UPD62AMC-710-5A4-E2
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD62AMC-711
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD62AMC-711
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD62AMC-713-5A4-E1
Manufacturer:
NEC
Quantity:
2 500
Part Number:
UPD62AMC-713-5A4-E1
Manufacturer:
NEC
Quantity:
1 697
Part Number:
UPD62AMC-713-5A4-E1
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD62AMC-738-5A4-E1
Manufacturer:
NEC
Quantity:
5 818
5.2 Standby Mode Setting and Release
standby mode to be set, the status flag (F) is required to have been cleared (to 0).
instruction operand. If the standby mode is released, the status flag (F) is set (to 1).
mode is not set. If the release condition is not met at this time, the status flag is cleared (to 0). If the release condition
is met, the status flag remains set (to 1).
executed, the standby mode is not set. Here, also, the status flag (F) is set (to 1).
The standby mode is set with the HALT #b
The standby mode is released by the release condition specified by the reset (RESET input; POC) or the HALT
Even when the HALT instruction is executed in a state in which the status flag (F) has been set (to 1), the standby
Even in the case when the release condition has already been met at the point that the HALT instruction is
Caution Depending on the status of the status flag (F), the HALT instruction may not be executed. Be
Example
careful about this. For example, when setting HALT mode after checking the key status with
the STTS instruction, because the system does not enter HALT mode as long as the status flag
(F) remains set (to 1), sometimes an unintended operation is performed. In this case, the
intended operation can be realized by executing the STTS instruction immediately after the
timer setting to clear (to 0) the status flag.
Reset
Release condition shown in Table 5-3
Table 5-2. Addresses Executed After Standby Mode Release
STTS
MOV
STTS
HALT
Release Condition
#03H
T, #0xxH
#05H
(During this time, be sure not to execute an instruction that may set the status flag.)
#05H
Data Sheet U14474EJ1V0DS00
3
;To check the K
;To set the timer
;To clear the status flag
;To set HALT mode
b
2
b
1
b
0
B instruction for both STOP mode and HALT mode. For the
0 address
The address following the HALT instruction
I
pin status.
Address Executed After Release
PD62A