IS46TR16128A-15HBLA2 ISSI, IS46TR16128A-15HBLA2 Datasheet - Page 12

no-image

IS46TR16128A-15HBLA2

Manufacturer Part Number
IS46TR16128A-15HBLA2
Description
DRAM 2G, 1.5v, 1333MT/s 128Mx16 DDR3
Manufacturer
ISSI

Specifications of IS46TR16128A-15HBLA2

Rohs
yes
Data Bus Width
16 bit
Organization
128 M x 16
Package / Case
FBGA-96
Memory Size
2 Gbit
Maximum Clock Frequency
933 MHz
Access Time
13.125 ns
Supply Voltage - Max
1.575 V
Supply Voltage - Min
1.425 V
Maximum Operating Current
65 mA
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
IS43/46TR16128A, IS43/46TR16128AL,
IS43/46TR82560A, IS43/46TR82560AL
Notes:
1. In case of burst length being fixed to 4 by MR0 setting, the internal write operation starts two clock cycles earlier than for the BL8 mode. This means
2. 0...7 bit number is value of CA[2:0] that causes this bit to be the first read during a burst.
3. T: Output driver for data and strobes are in high impedance.
4. V: a valid logic level (0 or 1), but respective buffer input ignores level on input pins.
5. X: Don’t Care.
2.3.2.2 CAS Latency
The CAS Latency is defined by MR0 (bits A9-A11) as shown in Figure 2.3.2. CAS Latency is the delay, in clock cycles,
between the internal Read command and the availability of the first bit of output data. DDR3 SDRAM does not support
any half-clock latencies. The overall Read Latency (RL) is defined as Additive Latency (AL) + CAS Latency (CL); RL = AL
+ CL. For more information on the supported CL and AL settings based on the operating clock frequency, refer to
“Standard Speed Bins”.
2.3.2.3 Test Mode
The normal operating mode is selected by MR0 (bit A7 = 0) and all other bits set to the desired values shown in Figure
2.3.2. Programming bit A7 to a ‘1’ places the DDR3 SDRAM into a test mode that is only used by the DRAM Manufacturer
and should NOT be used. No operations or functionality is specified if A7 = 1.
2.3.2.4 DLL Reset
The DLL Reset bit is self-clearing, meaning that it returns back to the value of ‘0’ after the DLL reset function has been
issued. Once the DLL is enabled, a subsequent DLL Reset should be applied. Any time that the DLL reset function is
used, tDLLK must be met before any functions that require the DLL can be used (i.e., Read commands or ODT
synchronous operations).
2.3.2.5 Write Recovery
The programmed WR value MR0 (bits A9, A10, and A11) is used for the auto precharge feature along with tRP to
determine tDAL. WR (write recovery for auto-precharge) min in clock cycles is calculated by dividing tWR (in ns) by tCK
Integrated Silicon Solution, Inc. – www.issi.com –
Rev. 00A
11/14/2012
Length
Burst
that the starting point for tWR and tWTR will be pulled in by two clocks. In case of burst length being selected on-the-fly via A12/BC#, the internal
write operation starts at the same point in time like a burst of 8 write operation. This means that during on-the-fly control, the starting point for tWR
and tWTR will not be pulled in by two clocks.
Chop
4
8
WRITE
WRITE
WRITE
READ/
READ
READ
(A2,A1,A0)
ADDRESS
Starting
Column
V,V,V
0,V,V
1,V,V
100
101
110
111
100
101
110
111
10
11
10
11
0
1
0
1
burst type = Sequential
0,1,2,3,X,X,X,X
4,5,6,7,X,X,X,X
0,1,2,3,T,T,T,T
1,2,3,0,T,T,T,T
2,3,0,1,T,T,T,T
3,0,1,2,T,T,T,T
4,5,6,7,T,T,T,T
5,6,7,4,T,T,T,T
6,7,4,5,T,T,T,T
7,4,5,6,T,T,T,T
0,1,2,3,4,5,6,7
1,2,3,0,5,6,7,4
2,3,0,1,6,7,4,5
3,0,1,2,7,4,5,6
4,5,6,7,0,1,2,3
5,6,7,4,1,2,3,0
6,7,4,5,2,3,0,1
7,4,5,6,3,0,1,2
0,1,2,3,4,5,6,7
(decimal)
A3 = 0
burst type = Interleaved
0,1,2,3,X,X,X,X
4,5,6,7,X,X,X,X
0,1,2,3,T,T,T,T
1,0,3,2,T,T,T,T
2,3,0,1,T,T,T,T
3,2,1,0,T,T,T,T
4,5,6,7,T,T,T,T
5,4,7,6,T,T,T,T
6,7,4,5,T,T,T,T
7,6,5,4,T,T,T,T
0,1,2,3,4,5,6,7
1,0,3,2,5,4,7,6
2,3,0,1,6,7,4,5
3,2,1,0,7,6,5,4
4,5,6,7,0,1,2,3
5,4,7,6,1,0,3,2
6,7,4,5,2,3,0,1
7,6,5,4,3,2,1,0
0,1,2,3,4,5,6,7
(decimal)
A3 = 1
1, 2, 4, 5
1, 2, 4, 5
Notes
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
2, 4
2
2
2
2
2
2
2
2
12