XRT83VSH314ES Exar, XRT83VSH314ES Datasheet - Page 41

no-image

XRT83VSH314ES

Manufacturer Part Number
XRT83VSH314ES
Description
Peripheral Drivers & Components - PCIs 14 CHT1/E1LIUSH LOW COST VERSION
Manufacturer
Exar
Datasheet

Specifications of XRT83VSH314ES

Product Category
Peripheral Drivers & Components - PCIs
Rohs
yes
REV. 1.0.1
For 1:1 or 1+1 line card redundancy in T1/E1 applications, power failure could cause a line card to change the
characteristics of the line impedance, causing a degradation in system performance. The XRT83VSH314 was
designed to ensure reliability during power failures. The LIU has patented high impedance circuits that allow
the receiver inputs and the transmitter outputs to be in "High" impedance when the LIU experiences a power
failure or when the LIU is powered off.
N
Physical layer devices such as LIUs that interface to telecommunications lines are exposed to overvoltage
transients posed by environmental threats. An Overvoltage transient is a pulse of energy concentrated over a
small period of time, usually under a few milliseconds. These pulses are random and exceed the operating
conditions of CMOS transceiver ICs. Electronic equipment connecting to data lines are susceptible to many
forms of overvoltage transients such as lightning, AC power faults and electrostatic discharge (ESD). There
are three important standards when designing a telecommunications system to withstand overvoltage
transients.
N
In non-intrusive monitoring applications, the transmitters are shut off by setting TxON "Low". The receivers
must be actively receiving data without interfering with the line impedance. The XRT83VSH314’s internal
termination ensures that the line termination meets T1/E1 specifications for 75Ω, 100Ω or 120Ω while
monitoring the data stream. System integrity is maintained by placing the non-intrusive receiver in "High"
impedance, equivalent to that of a 1+1 redundancy application. A simplified block diagram of non-intrusive
monitoring is shown in
F
5.4
5.5
5.6
OTE
OTE
IGURE
UL1950 and FCC Part 68
Telcordia (Bellcore) GR-1089
ITU-T K.20, K.21 and K.41
: For power failure protection, a transformer must be used to couple to the line interface. See the TAN-56 application
:
For a reference design and performance,
note for more details.
29. S
Power Failure Protection
Overvoltage and Overcurrent Protection
Non-Intrusive Monitoring
IMPLIFIED
XRT83VSH314
XRT83VSH314
Non-Intrusive Receiver
Line Card Transceiver
Figure
B
LOCK
29.
D
IAGRAM OF A
14-CHANNEL T1/E1/J1 SHORT-HAUL LINE INTERFACE UNIT
N
ON
see the TAN-54 application note for more details.
-I
NTRUSIVE
38
M
ONITORING
Data Traffic
A
PPLICATION
XRT83VSH314
Node

Related parts for XRT83VSH314ES