S-24CS16A0I-D8S1G Seiko Instruments, S-24CS16A0I-D8S1G Datasheet - Page 25

no-image

S-24CS16A0I-D8S1G

Manufacturer Part Number
S-24CS16A0I-D8S1G
Description
IC EEPROM 16KBIT 400KHZ 8DIP
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-24CS16A0I-D8S1G

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
16K (2K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-DIP
Organization
2 K x 8
Interface Type
2-Wire
Maximum Clock Frequency
0.4 MHz
Access Time
1 us
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Maximum Operating Current
4 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.8 V, 5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rev.5.2
6. Data hold time (t
7. SDA pin and SCL pin noise suppression time
If SCL and SDA of the E
being mistakenly recognized due to the effect of noise. If a start/stop condition is mistakenly recognized during
communication, the E
It is recommended that SDA is delayed from the falling edge of SCL by 0.3 µ s minimum in the S-24CS16A. This is to
prevent time lag caused by the load of the bus line from generating the stop (or start) condition.
The S-24CS16A includes a built-in low-pass filter to suppress noise at the SDA and SCL pins. This means that if the
power supply voltage is 5.0 V, noise with a pulse width of 160 ns or less can be suppressed.
The guaranteed for details, refer to noise suppression time (t
_00
Noise suppression time (t
SDA
SCL
HD.DAT
2
PROM enters the standby status.
2
PROM are changed at the same time, it is necessary to prevent the start / stop condition from
Figure 31 Noise Suppression Time for SDA and SCL Pins
= 0 ns)
[ns]
Figure 30 E
I
) Max.
Seiko Instruments Inc.
2
t
PROM Data Hold Time
HD.DAT
300
200
100
= 0.3 µs Min.
I
) in Table 13 .
Power supply voltage (V
2
3
2-WIRE CMOS SERIAL E
[V]
4
5
CC
)
S-24CS16A
2
PROM
25