HCNR201-300E Avago Technologies US Inc., HCNR201-300E Datasheet - Page 6

OPTOCOUPLER ANLG DC-1MHZ GW 8SMD

HCNR201-300E

Manufacturer Part Number
HCNR201-300E
Description
OPTOCOUPLER ANLG DC-1MHZ GW 8SMD
Manufacturer
Avago Technologies US Inc.
Datasheets

Specifications of HCNR201-300E

Output Type
Linear Photovoltaic
Input Type
DC
Package / Case
8-SMD Gull Wing
Number Of Channels
1
Voltage - Isolation
5000Vrms
Current Transfer Ratio (min)
0.36% @ 10mA
Current Transfer Ratio (max)
0.72% @ 10mA
Current - Dc Forward (if)
25mA
Mounting Type
Surface Mount, Gull Wing
Current Transfer Ratio
0.36 % to 0.72 %
Forward Current
1 mA to 20 mA
Isolation Voltage
5000 Vrms
Minimum Forward Diode Voltage
1.2 V
Output Device
Photodiode
Configuration
1 Channel
Maximum Forward Diode Voltage
1.95 V
Maximum Reverse Diode Voltage
2.5 V
Maximum Input Diode Current
25 mA
Maximum Power Dissipation
60 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 55 C
No. Of Channels
1
Optocoupler Output Type
Photodiode
Input Current
20mA
Output Voltage
15V
Opto Case Style
SMD
No. Of Pins
8
Forward Voltage
1.6V
Rohs Compliant
Yes
Forward Current If
25mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Current - Output / Channel
-
Vce Saturation (max)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
516-1609-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCNR201-300E
Manufacturer:
AVAGO
Quantity:
30 000
Insulation and Safety Related Specifications
Min. External Clearance
(External Air Gap)
Min. External Creepage
(External Tracking Path)
Min. Internal Clearance
(Internal Plastic Gap)
Min. Internal Creepage
(Internal Tracking Path)
Comparative Tracking Index
Isolation Group
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option #050 Only)
*Refer to the front of the Optocoupler section of the current catalog for a more detailed description of IEC/EN/DIN EN 60747‑5‑2 and other prod‑
uct safety regulations.
Note: Optocouplers providing safe electrical separation per IEC/EN/DIN EN 60747‑5‑2 do so only within the safety‑limiting values to which they
are qualified. Protective cut‑out switches must be used to ensure that the safety limits are not exceeded.
6
Parameter
Description
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage ≤600 V rms
For rated mains voltage ≤1000 V rms
Climatic Classification (DIN IEC 68 part 1)
Pollution Degree (DIN VDE 0110 Part 1/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
t
Input to Output Test Voltage, Method a*
V
Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety‑Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 11)
Case Temperature
Current (Input Current I
Output Power
Insulation Resistance at T
PR
m
PR
= 1 sec, Partial Discharge < 5 pC
= 1.875 x V
= 1.5 x V
IORM
IORM
, Type and sample test, t
, 100% Production Test with
S
, V
ini
IO
F
= 10 sec)
, P
= 500 V
S
= 0)
Symbol
L(IO1)
L(IO2)
CTI
m
= 60 sec,
Value
10.0
200
9.6
1.0
4.0
IIIa
Units
mm
mm
mm
mm
V
Conditions
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Through insulation distance conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity
The shortest distance around the border
between two different insulating materials
measured between the emitter and detector
DIN IEC 112/VDE 0303 PART 1
Material group (DIN VDE 0110)
P
Symbol
S,OUTPUT
V
V
V
V
IORM
T
R
IOTM
I
PR
PR
S
S
S
Characteristic
55/100/21
1414
2651
2121
8000
>10
150
400
700
I‑IV
I‑III
2
9
V
V
V
V
Unit
mW
mA
°C
Ω
peak
peak
peak
peak

Related parts for HCNR201-300E