Specifications of TLP190B(U,C,F)

Number Of Channels
1
Input Type
DC
Voltage - Isolation
2500Vrms
Voltage - Output
8V
Current - Output / Channel
20µA
Current - Dc Forward (if)
50mA
Output Type
Photovoltaic
Mounting Type
Surface Mount
Package / Case
6-MFSOP (4 Lead)
Configuration
1 Channel
Maximum Collector Emitter Voltage
3 V
Maximum Forward Diode Voltage
1.7 V
Maximum Reverse Diode Voltage
3 V
Maximum Rise Time
0.2 ms
Maximum Fall Time
1 ms
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Maximum Input Diode Current
50 mA
Output Device
Photovoltaic
Number Of Elements
1
Reverse Breakdown Voltage
3V
Forward Voltage
1.7V
Forward Current
50mA
Collector-emitter Voltage
Not RequiredV
Package Type
MFSOP
Collector Current (dc) (max)
Not RequiredA
Isolation Voltage
2500Vrms
Collector-emitter Saturation Voltage
Not RequiredV
Current Transfer Ratio
Not Required%
Pin Count
4
Mounting
Surface Mount
Operating Temp Range
-25C to 85C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Vce Saturation (max)
-
Current Transfer Ratio (max)
-
Current Transfer Ratio (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
TLP190B
TLP190B
TLP190BF
9
For example, let's calculate the operating life of the GaAs LED, based on the data shown on page 60.
Here is an example of how to read an operating life, assuming that the ambient temperature (Ta) is 40°C and that the failure
criterion is a 30% decrease in light output.
Suppose that the initial LED current, IF, is 20 mA. Since the horizontal axis of the failure criteria graph is the reciprocal of absolute
temperature, it is necessary to convert the ambient temperature (Ta) to the reciprocal of absolute temperature (T):
The graph shows the projected lifetimes for F50% and F0.1% cumulative failure probabilities in solid and dashed lines respectively.
Normally, it is recommended to use F0.1% lines.
As X = 3.19, its intersection with the IF = 20 mA line for F0.1% is approximately 80,000 hours. (This figure is for reference only.)
You can also estimate the projected operating life from the projected light output degradation data.
Reading the Projected LED Operating Life Graph
Device Degradation
T =
Ta + 273.15
1
=
10000000
1000000
100000
40 + 273.15
80000
10000
1000
140
120
100
100
80
70
60
40
20
0
227
2.0
1
1
–30%
I
I
I
I
I
F
F
F
F
F
150
Failure criteria for light output degradation Δ P O < –30%
= 10mA
= 20mA
= 30mA
= 40mA
= 50mA
10
3.19 × 10
100 85
Test conditions: I
3.0
60
3.19
100
−3
40
Test time (h)
64
F
25
= 20 mA, Ta = 40°C
1000
0
4.0
I
I
I
I
I
−20
F
F
F
F
F
= 10mA
= 20mA
= 30mA
= 40mA
= 50mA
Projected F50%
operating life
Projected F0.1%
operating life
Ambient Temperature (°C)
10000
X-3σ
−50
1/K(×10
X
80000
100000
−73
5.0
–3
)

Related parts for TLP190B(U,C,F)