TLP3042SCFT Toshiba, TLP3042SCFT Datasheet - Page 72

PHOTOCOUPLER ZC TRIAC OUT 6-DIP

TLP3042SCFT

Manufacturer Part Number
TLP3042SCFT
Description
PHOTOCOUPLER ZC TRIAC OUT 6-DIP
Manufacturer
Toshiba
Datasheets

Specifications of TLP3042SCFT

Voltage - Isolation
5000Vrms
Number Of Channels
1
Voltage - Off State
400V
Output Type
AC, Triac, Zero Cross
Current - Gate Trigger (igt) (max)
10mA
Current - Hold (ih)
600µA
Current - Dc Forward (if)
20mA
Current - Output / Channel
100mA
Mounting Type
Through Hole
Package / Case
6-DIP
Output Device
PhotoTriac
Isolation Voltage
5000 V
Peak Output Voltage (vdrm)
400 V
Maximum Input Voltage
120 VAC
Maximum Output Voltage
400 V
Minimum Trigger Current
5 mA
Configuration
1 Channel
Maximum Continuous Output Current
100 mA
Maximum Input Current
25 mA
Maximum Operating Temperature
+ 100 C
Maximum Power Dissipation
330 mW
Maximum Reverse Diode Voltage
5 V
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Zero-crossing Circuit
Yes
Number Of Elements
1
Forward Voltage
1.3V
Repetitive Peak Off-state Volt
400V
Operating Temp Range
-25C to 85C
Output Current
100mA
Package Type
PDIP
Reverse Breakdown Voltage
5V
Mounting
Through Hole
Pin Count
5
Trigger Current
5mA
Zero Crossing Circuit
Yes
Operating Temperature Classification
Commercial
Forward Current
50mA
Power Dissipation
330mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
TLP3042(S,C,F)
TLP3042(S,C,F,T)
TLP3042SF
11
(2)Waveform Examples
4
Inverter Air Conditioners
Home Appliance Applications
Indoor Unit
Outdoor Unit
IGBT Gate
Drive Circuit
Temperature Sensor
Room Temperature
Photocoupler Application Circuit Examples
Remote Control
Control Panel
Sensor
Panel
waveforms
1.
Example of Operating Waveform for Burner Motor
TLP351
Top:
Medium:
Bottom:
Horizontal:
x
Microcontroller
Microcontroller
TLP781
TLP548J
TLP781
TLP548J
6
for Outdoor
for Indoor
Unit
Unit
V
V
CC
O
I
V
I
time
F1
M1
T1
20 mA/div
100 V/div
1 A/div
50 ms/div
Trigger Point
( Continued )
TLP560G
TLP560G
IGBT Module
ZC
72
waveforms
2.
Example of Operating Waveform for Fan Motor
Top:
Medium:
Bottom:
Horizontal:
Compressor
Motor
Temperature Fuse
I
V
I
time
F2
M2
T2
Motor for Air-Flow
Direction Control
Two-Way Valve /
Four-Way Valve
Fan Motor for
Fan Motor for
Outdoor Unit
Room Unit
Rectifier
20 mA/div
100 V/div
0.5 A/div
50 ms/div
Filter
Trigger Point
M
M
M
100 Vac

Related parts for TLP3042SCFT