ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 11

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
1.1 USER’S MANUAL CONTENT
This user’s manual contains the operating instructions, installation instructions and specifications of
the ZUP series. For information related to operation with GPIB control, refer to Nemic-Lambda GP485
user’s manual.
1.2 INTRODUCTION
1.2.1 General description
1.2.2 Configurations
1.2.3 Control via the serial communication port
The ZUP series are wide range output switching power supplies with laboratory performance. The ZUP
series is power factor corrected and operates from worldwide AC voltage range continuously. Output
voltage and current are continuously displayed and LED indicators show the complete operating status
of the power supply. The front panel controls allow the user to set the output parameters, the protection
levels (over-voltage / under-voltage)and arm the foldback protection to disable the output if the unit
switches from Constant-voltage mode to Constant-current mode.
The ZUP can be configured into a programmable power system of up to 31 DC outputs using the built-in
RS232 or RS485 communication port in the power supply. In a GPIB system the GP485 controller can
control up to 31 ZUP units in a single GPIB address.
The following parameters can be programmed via the serial communication port:
Output connections are made to rear panel bus-bars for models up to 60V and connector for the 80V
and 120V models. Either the positive or negative terminal may be grounded or the output may be
floated. The maximum potential (including the output voltage) that either output terminal is from ground
must not exceed the rated output voltage. Local or remote sense may be used. In remote sense, the
maximum voltage drop on each wire is 0.5V for models up to 60V and 2V for the 80V and 120V models.
1.2.4 Output connections
1.2.5 Analog voltage programming
1.2.6 Parallel operation
Analog inputs are provided at the rear panel for analog voltage programming of output voltage and
current, and On/Off control. Inputs are provided for resistive programming of the output voltage and
current.
Zup units of the same output voltage and current rating can be paralleled in master-slave configuration
with automatic current sharing for power-up purposes.
CHAPTER 1 GENERAL INFORMATION
1. Output voltage setting
2. Output current setting
3. Output On/Off
4. Arming or release of the foldback protection
5. Over-voltage protection setting
6. ‘Soft’ under-voltage limit
7. Output voltage measurement
10. Over-voltage protection setting read
11. Under-voltage limit read
12. Remote/Local Control
8. Output current measurement
9. Power supply start-up mode
(last setting or safe mode)