ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 19

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
This power supply is equipped with a three conductor power cable. The third conductor is the ground
conductor. When the cable is plugged-in to an appropriate receptacle, the power supply is grounded.
Under no circumstances should this power supply be operated without an adequate ground
connection. If a two contact receptacle is encountered, it must be replaced by a three contact
receptacle, properly grounded. This operation should be done by a qualified electrician. It is
recommended to keep the AC input wires separate from the DC output and signal wires to avoid
interference.
To meet radiated EMI specification, the EMI suppressor clamp should be attached to the AC cable as
close as possible to the AC inlet of the power supply.
3.7 CONNECTING THE LOAD
Turn off the AC input power before making or changing any rear panel connection.
Make sure that all connections are securely tightened before applying power.
There is a potential shock hazard when using a power supply with a rated output greater than 40V.
Use load wiring with a minimum insulation rating equivalent to the maximum output voltage of the
power supply.
3.7.1 Selecting wire size
Two factors must be considered in selecting wire size.
1. Wires should be at least heavy enough to avoid overheating while carrying the power supply load
current at the rated load, or the current that would flow in the event the load wire were shorted,
whichever is greater.
2. Wire size should be selected to enable voltage drop per lead to be less than 0.5V at the rated current.
It is recommended to minimize voltage drop on the wires to prevent excessive output power
consumption from the power supply.
Please refer to Tables 3-1 and 3-2 for maximum wire length to limit voltage drop by American and
European measurements respectively.
14
12
10
8
6
4
2
0
2.526
1.589
0.9994
0.6285
0.3953
0.2486
0.1564
0.0983
Some components inside the power supply are at AC voltage even when the
On/Off switch is in the “Off” position. To avoid the hazard of electric shock,
disconnect line cord and load and wait 2 minutes before removing cover.
1016
100
160
253
400
640
5A
Maximum length in feet -
to limit voltage drop to 0.5V or less
40
63
10A
126
200
320
508
20
31
50
80
20A
100
160
254
10
15
25
40
63
WARNING
WARNING
50A
102
10
16
25
40
64
4
6
150A
1.7
13
21
34
1
3
5
8
Table 3-1: Maximum wire length for
0.5V drop on lead (in feet)