ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 49

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
5.5.3 Output control
2
3
#
1
4
:VOL?;
:CURn;
:VOL!;
Commands
:VOLn;
Returns the string
output voltage value. The actual voltage range is as shown in table 5-1.
example: SV5.010
Table 5-2: Current programming range.
Returns the string
The actual voltage range is the same as the programming range.
example: AV5.010 AV08.500
Sets the output current in Ampers. This programmed current is the actual
output current at constant-current mode or the current limit at constant
voltage mode. The programming range is shown in table 5-2:
Use all digits for current programming.
Sets the output voltage value in volts. This programmed voltage is the
actual output at constant-voltage mode or the voltage limit at constant
current mode. The range of the voltage values are as shown in table 5-1.
Use all digits for voltage programming
Table 5-1: Voltage programming range.
Example - ZUP6-XY :VOL5.010;
Description
Example - ZUP60-3.5 :CUR3.000;
ZUP6-XY
ZUP10-XY
ZUP20-XY
ZUP36-XY
ZUP60-XY
ZUP80-XY
ZUP120-XY
Model
ZUP6-33
ZUP6-66
ZUP6-132
ZUP10-20
ZUP10-40
ZUP10-80
ZUP20-10
ZUP20-20
ZUP20-40
ZUP36-6
ZUP36-12
ZUP36-24
ZUP60-3.5
ZUP60-7
ZUP60-14
ZUP80-2.5
ZUP80-5
ZUP120-1.8
ZUP120-3.6
Model
000.00
00.000
00.000
00.000
00.000
00.000
00.000
0.0000
0.0000
00.000
00.000
00.00
00.00
00.00
00.00
00.00
0.000
0.000
0.000
0.000
0.000
MIN.
0.000
00.00
00.00
00.00
000.00
MIN.
AV
SV
(Actual Voltage) followed by the actual output voltage.
(Set Voltage) followed by the present programmed
132.00
20.000
10.000
20.000
12.000
24.000
14.000
2.5000
1.8000
3.600
MAX.
33.00
66.00
40.00
80.00
40.00
6.000
3.500
7.000
5.000
SV08.500
10.000
20.000
120.00
MAX.
6.000
36.00
60.00
80.00
Note:
The ZUP can accept values higher by 5%
than the rating. It is recommended to set the
output current to 105% of the rating if the
unit is required to supply the rated current.
Note:
The ZUP can accept programmed value
higher by up to 5% than the table values,
however it is not recommended to program
power supply over the rated voltage.
ZUP10-XY :VOL08.500;
ZUP10-40 :CUR07.50;

Related parts for ZUP20-10/U