ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 29

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
Table 4-1: Front panel controls and indicators
1
2
3
4
5
9
6
7
8
#
AMPS Display
VOLTS Display
CV Indicator
CC Indicator
ADJUST knob
ALM Indicator
(Rotary pulse generator)
OUT Pushbutton
REM Pushbutton
FOLD Pushbutton
Control/Indicator
Description
Actual output current display at normal operation. While
adjusting the output current, the set value will be shown.
The display will automatically return to show the actual
current approx. 3sec from completion of adjustment.
Actual output voltage display at normal operation. The
measurement circuits monitor the voltage at the sensing
points, hence at remote sensing where there is voltage
drop on the load wires, the voltage at the power supply
output terminals will be higher than the displayed value.
Attention should be taken not to exceed the output power
rating. While adjusting the output voltage, the set value will
be shown. The display will automatically return to show the
actual voltage approx. 3sec after completion of adjustment.
CV LED indicates that the power supply is regulating it’s
output at a constant voltage.
CC LED indicates that the power supply is regulating it’s
output at a constant current.
The ADJUST knob functions to determine the following
output parameters:
1. Output voltage adjust - as determined by V/A pushbutton
2. Output current adjust - as determined by V/A pushbutton
3. Over voltage protection adjust - as determined by
4. Under voltage soft limit adjust-as determined
5. Address selection
ALM indicates alarm caused by activation of one of the
following protections:
* Over voltage protection
* Over temperature protection
* Foldback protection
Main function: Enable or disable the power supply output.
Auxiliary function: Press and hold OUT pushbutton for
approx. 3sec to change function to select between safe
mode restart and automatic restart.
Main function: Select between local or remote operation.
Auxiliary function: Press and hold REM pushbutton for
approx. 3sec to change function to select between RS232
or RS485 communication.
Pressing FOLD pushbutton arms foldback protection
which shuts down output if supply transits from CV to CC.
OVP/UVP pushbutton
by OVP/UVP pushbutton
5.2.1
4.4.2
4.4.3
4.4.5
4.4.6
4.4.7
5.2.4
4.4.8
4.4.9
Par.

Related parts for ZUP20-10/U