DEMOBOARD TLE 6214L Infineon Technologies, DEMOBOARD TLE 6214L Datasheet - Page 11

BOARD DEMO FOR TLE 6214L

DEMOBOARD TLE 6214L

Manufacturer Part Number
DEMOBOARD TLE 6214L
Description
BOARD DEMO FOR TLE 6214L
Manufacturer
Infineon Technologies
Datasheet

Specifications of DEMOBOARD TLE 6214L

Main Purpose
Power Management, Low Side Driver (Internal FET)
Embedded
No
Utilized Ic / Part
TLE6214
Primary Attributes
2 Channel Internal Switch
Secondary Attributes
Overvoltage, Short-Circuit & Thermal Protection
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DEMOBOARDTLE6214LIN
Fig. 1 : Two bits per channel diagnostic feedback plus two overtemperature flags
For Full Diagnosis there are two diagnostic bits per channel configured as shown in Figure 1.
Bit 6 and bit 7 of the diagnostic register are not used and always H.
Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function.
Overload, Shorted Load or Overtemperature: HL is set when the current limitation gets active, i.e.
there is a overload, short to supply or overtemperature condition. The second reason for this bit combi-
nation is overtemperature of the corresponding channel.
Open load/ Under current: LH is set when open load (in off state of the channel) or under current (in
on state of the channel) is detected
Short to GND : LL is set when this condition is detected (in off state)
Channel Overtemperature Flag: In case of overtemperature in any output channel in on state the
overtemperature Flag in the SPI diagnosis register is set. This Bit can be used to distinguish between
Overload and Overtemperature (both HL combination).
IC Overtemperature Warning Flag: When the IC logic temperature exceeds typ.170° the IC
Overtemperature Warning Flag will be set in the SPI diagnosis register.
Parallel Status Output Diagnostics :
Parallel diagnostic outputs (open drain) change state according to the input signal of the corresponding
channel. As soon as an error occurs at the corresponding channel ( Overload, Overtemperature and
Under current is detected in on state and Open load, short to GND also in off state) the Status output
shows the inverted input signal. A fault is detected only if it lasts for longer than the fault filtering time.
This fault information is not latched.
If a CS Low to High transition is received the fault filtering time for parallel status output diagnostic is
restarted (If a valid command was in the SPI register).
V3.0
Diagnostic Serial Data O ut SO
H H
H L
LH
LL
M SB
N orm al function
O verload , Shorted Load or O verte m perature
O pen Load (off), U nder C u rrent (on)
Short to G N D
7
6
C h .2
5
Channel O vertem -
perature Flag
4
C h.1
Page
3
2
11
1
LSB
0
IC Overtem -
perature Flag
Datasheet TLE 6214 L