M38000T2-CPE User’s Manual
(2) Suspending and resuming trace measurement
1. Suspending trace measurement
2. Resuming trace measurement
(3) Trace point setup dialog box
1. Opening the trace point setup dialog box
2. Trace Point Setting Window in initial state
R20UT0213EJ0600 Rev.6.00
Oct. 20, 2010
Stop
Click this toolbar button to suspend the trace measurement
in progress.
Re-Start
Click this toolbar button to resume the trace measurement in
progress.
Trace Point
Clicking this toolbar button opens the trace point setting
window.
Or you can select “Trace point” from “Trace” of “Display”
menu for the same effect.
Trace Point Setting Window in initial state
You can specify following two trace ranges for the trace
event.
- Before Break
- After Go
32K cycles of instruction execution after a trace began is
recorded.
32K cycles of instruction execution before the user
program stopped is recorded.
3. Usage (How to Use the Emulator Debugger)