EVALPM6680 STMicroelectronics, EVALPM6680 Datasheet - Page 31

no-image

EVALPM6680

Manufacturer Part Number
EVALPM6680
Description
BOARD EVALUATION FOR PM6680
Manufacturer
STMicroelectronics
Datasheet

Specifications of EVALPM6680

Mfg Application Notes
PM6680 Eval Kit, AN2566 App Note
Main Purpose
DC/DC, Step Down with LDO
Outputs And Type
3, Non-Isolated
Power - Output
13.25W
Voltage - Output
1.05V, 1.5V, 5V
Current - Output
5A, 5A, 100mA
Voltage - Input
6 ~ 28V
Regulator Topology
Buck
Frequency - Switching
200kHz, 300kHz
Board Type
Fully Populated
Utilized Ic / Part
PM6680
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6241

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVALPM6680
Manufacturer:
ST
0
Part Number:
EVALPM6680A
Manufacturer:
ST
0
PM6680
7.12
7.12.1
7.12.2
7.12.3
7.12.4
Monitoring and protections
Power good signals
The PM6680 provides three independent power good signals: one for each switching
section (PGOOD1/PGOOD2).
point or during the soft-start, the soft end and when the device works in standby and
shutdown mode.
Thermal protection
The PM6680 has a thermal protection to preserve the device from overheating. The thermal
shutdown occurs when the die temperature goes above +150 °C. In this case all internal
circuitry is turned off and the power sections are turned off after the discharge mode.
A power on reset or a toggle on the SHDN pin is necessary to restart the device.
Overvoltage protection
When the switching output voltage is about 115 % of its nominal value, a latched
overvoltage protection occurs. In this case, the synchronous rectifier immediately turns on
while the high-side MOSFET turns off. The output capacitor is rapidly discharged and the
load is preserved from being damaged. The overvoltage protection is also active during the
soft start. Once an overvoltage protection has been detected, a toggle on SHDN, EN1/EN2
pins or a power on reset is necessary to exit from the latched state.
Undervoltage protection
When the switching output voltage is below 70 % of its nominal value, a latched
undervoltage protection occurs. In this case the switching section is immediately disabled
and both switches are open. The controller enters in soft end mode and the output is
eventually kept to ground, turning low side MOSFET on. The undervoltage circuit protection
is enabled only at the end of the soft-start. Once an overvoltage protection has been
detected, a toggle on SHDN, EN1/EN2 pin or a power on reset is necessary to clear the
undervoltage fault and starts with a new soft-start phase.
Table 9.
PGOOD1/PGOOD2 signals are low if the output voltage is out of ±10 % of the designed set
Undervoltage
Overvoltage
protection
protection
shutdown
Thermal
Mode
Protections and operatives modes
OUT1/OUT2 > 115 % of
the nominal value
OUT1/OUT2 < 70 % of the
nominal value
T
J
> +150 ºC
Conditions
LGATE1/LGATE2 pin is forced high, LDO5 remains
active. Exit by a power on reset or toggling SHDN or
EN1/EN2
LGATE1/LGATE2 is forced high after the soft end
mode, LDO5 remains active. Exit by a power on reset
or toggling SHDN or EN1/EN2
All circuitry off. Exit by a POR on VIN or toggling
SHDN.