CHIPPROG-40 Phyton Inc, CHIPPROG-40 Datasheet - Page 113

PROGRAMMER STANDALONE 40-DIP

CHIPPROG-40

Manufacturer Part Number
CHIPPROG-40
Description
PROGRAMMER STANDALONE 40-DIP
Manufacturer
Phyton Inc
Type
Universal, Stand Aloner
Datasheets

Specifications of CHIPPROG-40

Contents
Programmer, Cables, CD, Power Adapter
Ic Product Type
Programmer, Universal
Ic Interface Type
USB
Features
Embedded Script Language For Automation Of Routine Operations, Splits Files To Multiple Images
Rohs Compliant
Yes
For Use With/related Products
EEPROM, EPROM, FLASH, MCU, NVRAM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
© 2010 Phyton, Inc. Microsystems and Development Tools
6.2.17 ACI_AllProgOptionsDefault
6.2.18 ACI_ExecFunction
See also the
ACI_FUNC ACI_AllProgOptionsDefault();
Description
This function sets default device-specific options and parameters specified in the
Algorithm Parameters Editor
device manufacturers in the device data sheets.
ACI_FUNC ACI_ExecFunction( * params);
programmed. It actually writes to some virtual memory locations in the host PC's RAM, associated
with physical locations in the target device's memory and registers. In order to complete programming
the device parameters and to physically program them into the device's memory you should execute
an appropriate Program command (function) in the command group Device Parameters by means of
the
Note! This function does not physically restore the default settings into the device being
programmed. It actually writes to some virtual memory locations in the host PC's RAM, associated
with physical locations in the target device's memory and registers. In order to complete programming
the device parameters and to physically fix them in the device's memory you should execute an
appropriate Program command (function) in the command group Device Parameters by means of
the
This function does not physically write the specified information into the device being
ACI_ExecFunctionACI_StartFunction
ACI_ExecFunction
ACI_ProgOption_Params
or
ACI_StartFunction
window. These default parameter sets vary. They are defined by the
structure description.
with appropriate attributes.
with appropriate attributes.
Programming Automation via DLL
Device and
113