R99-11 Omron, R99-11 Datasheet - Page 3

MOUNTING BRACKET FOR G3NA RELAY

R99-11

Manufacturer Part Number
R99-11
Description
MOUNTING BRACKET FOR G3NA RELAY
Manufacturer
Omron
Series
G3NAr
Datasheets

Specifications of R99-11

Accessory Type
Mounting Bracket, Plate
Associated Relay Series
G3NA-240B, G3NA-440B(-2)
Termination Style
Screw
Mounting Style
Screw
Width
16 mm
For Use With/related Products
G3NA-240B and G3NA-440B
For Use With
Z2588 - RELAY SSR 40A 5VDCZ2587 - RELAY SSR 40A 230VACZ173 - RELAY SSR 40A@220VAC ZERO CROSSZ174 - RELAY SSR 40A@220VAC ZERO CROSSZ172 - RELAY SSR 40A@220VAC ZERO CROSS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R99-11
R9911
R9911NC
Z2000
Specifications
■ Input Ratings
(Ambient temperature: 25°C [77°F])
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
■ Output Ratings
G3NA-2❏❏B
G3NA-4❏❏B
G3NA-D210B
G3NA-275B-UTU
G3NA-290B-UTU
G3NA-475B-UTU
G3NA-490B-UTU
G3NA-205B
G3NA-210B
G3NA-410B
G3NA-220B
G3NA-420B
G3NA-240B
G3NA-440B
G3NA-450B
G3NA-D210B
G3NA-275B-UTU 24 to 240 VAC
G3NA-475B-UTU 200 to 480 VAC
G3NA-290B-UTU 24 to 240 VAC
G3NA-490B-UTU 200 to 480 VAC
*When the appropriate size OMRON heat sink is used.
2. With constant current input circuit system, the impedance for the G3NA-2❏❏B-UTU is 15mA max.
3. Refer to the “Characteristic Data” for further details.
Type
Type
the input impedance is measured at 120 VAC).
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
24 to 240 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
200 to 480 VAC
5 to 200 VDC
load voltage
voltage
Rated
Rated
4 to 32 VDC
75 to 132 VAC
150 to 264 VAC
4 to 32 VDC
75 to 264 VAC
4 to 32 VDC
75 to 264 VAC
19 to 264 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
180 to 528 VAC
4 to 220 VDC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
voltage range
voltage range
Operating
Load
7 mA max.
36 kΩ ±20%
72 kΩ ±20%
5 mA max.
72 kΩ ±20%
15 mA max.
72 kΩ ±20%
0.1 to 5 A (at 40°C)
0.1 to 10 A (at 40°C)
0.2 to 10 A (at 40°C)
0.1 to 20 A (at 40°C)
0.2 to 20 A (at 40°C)
0.1 to 40 A (at 40°C)
0.2 to 40 A (at 40°C)
0.2 to 50 A (at 40°C)
0.1 to 10 A (at 40°C)
1 to 75 A (at 40°C)
1 to 75 A (at 40°C)
1 to 90 A (at 40°C)
1 to 90 A (at 40°C)
With heat sink*
(See note 1)
Impedance
Applicable load
(see note 2)
(see note 2)
(see note 2)
Load current
4 VDC max.
75 VAC max.
150 VAC max.
4 VDC max.
75 VAC max.
4 VDC max.
75 VAC max.
0.1 to 3 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
0.1 to 4 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
Must operate voltage
Solid State Relay
Without heat sink
(see note 3)
(see note 3)
Voltage level
1 VDC min.
20 VAC min.
40 VAC min.
1 VDC min.
20 VAC min.
1 VDC min.
20 VAC min.
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
20 A (10 ms)
800 A (60 Hz, 1 cycle)
800 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
G3NA
Must release voltage
Surge current
(see note 3)
(see note 3)
453

Related parts for R99-11