M30620FCAFP#U5 Renesas Electronics America, M30620FCAFP#U5 Datasheet - Page 229

IC M16C MCU FLASH 100QFP

M30620FCAFP#U5

Manufacturer Part Number
M30620FCAFP#U5
Description
IC M16C MCU FLASH 100QFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheets

Specifications of M30620FCAFP#U5

Core Processor
M16C/60
Core Size
16-Bit
Speed
16MHz
Connectivity
SIO, UART/USART
Peripherals
DMA, PWM, WDT
Number Of I /o
85
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
10K x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-QFP
Package
100PQFP
Family Name
M16C
Maximum Speed
16 MHz
Operating Supply Voltage
5 V
Data Bus Width
16|32 Bit
Number Of Programmable I/os
87
Interface Type
SIM/UART
On-chip Adc
10-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
11
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30620FCAFP#U5M30620FCAFP
Manufacturer:
QFP
Quantity:
513
Company:
Part Number:
M30620FCAFP#U5M30620FCAFP
Quantity:
1 640
Company:
Part Number:
M30620FCAFP#U5M30620FCAFP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
M30620FCAFP#U5M30620FCAFP#D3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30620FCAFP#U5M30620FCAFP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
CPU Rewrite Mode (Flash Memory Version)
226
Figure 1.26.5. Block erase flowchart
Block Erase Command (20
By writing the command code “20
in the second bus cycle that follows to the block address of a flash memory block, the system initiates
an auto erase (erase and erase verify) operation.
Whether the auto erase operation is completed can be confirmed by reading the status register or the
flash memory control register 0. At the same time the auto erase operation starts, the read status
register mode is automatically entered, so the content of the status register can be read out. The
status register bit 7 (SR7) is set to 0 at the same time the auto erase operation starts and is returned
to 1 upon completion of the auto erase operation. In this case, the read status register mode remains
active until the Read Array command (FF
flash memory is reset using its reset bit.
The RY/BY status flag of the flash memory control register 0 is 0 during auto erase operation and 1
when the auto erase operation is completed as is the status register bit 7.
After the auto erase operation is completed, the status register can be read out to know the result of
the auto erase operation. For details, refer to the section where the status register is detailed.
Figure 1.26.5 shows an example of a block erase flowchart.
Each block of the flash memory can be protected against erasure by using a lock bit. For details, refer
to the section where the data protect function is detailed.
____
16
/D0
16
16
)
Note: Refer to Figure 1.26.8.
” in the first bus cycle and the confirmation command code “D0
RY/BY status flag
Check full status
Block address
check(Note)
Write D0
Block erase
16
Write 20
completed
) or Read Lock Bit Status command (71
Start
= 1?
YES
16
16
NO
Error
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Erase error
M16C / 62A Group
16
Mitsubishi microcomputers
) is written or the
16

Related parts for M30620FCAFP#U5