UPD70F3744GJ-GAE-AX Renesas Electronics America, UPD70F3744GJ-GAE-AX Datasheet - Page 438

no-image

UPD70F3744GJ-GAE-AX

Manufacturer Part Number
UPD70F3744GJ-GAE-AX
Description
MCU 32BIT V850ES/JX3 144-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3r
Datasheet

Specifications of UPD70F3744GJ-GAE-AX

Core Processor
RISC
Core Size
32-Bit
Speed
32MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
128
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3744GJ-GAE-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JJ3
12.5 Usage
12.6 Cautions
R01UH0016EJ0400 Rev.4.00
Sep 30, 2010
(1) Disable real-time output.
(2) Perform initialization as follows.
(3) Enable real-time output.
(4) Set the next output value to the RTBHn and RTBLn registers by the time the selected transfer trigger is
(5) Set the next real-time output value to the RTBHn and RTBLn registers via interrupt servicing corresponding to the
(1) Prevent the following conflicts by software.
(2) Before performing initialization, disable real-time output (RTPOEn bit = 0).
(3) Once real-time output has been disabled (RTPOEn bit = 0), be sure to initialize the RTBHn and RTBLn registers
Clear the RTPCn.RTPOEn bit to 0.
• Set the alternate-function pins of port 5
• Specify the real-time output port mode or port mode in 1-bit units.
• Channel configuration: Select the trigger and valid edge.
• Set the initial values to the RTBHn and RTBLn registers
Set the RTPOEn bit = 1.
generated
selected trigger.
Notes 1. If the RTBHn and RTBLn registers are written when the RTPOEn bit = 0, that value is transferred to
• Conflict between real-time output disable/enable switching (RTPOEn bit) and selected real-time output trigger.
• Conflict between writing to the RTBHn and RTBLn registers in the real-time output enabled status and the
before enabling real-time output again (RTPOEn bit = 0 → 1).
Set the PFC5.PFC5m bit and PFCE5.PFCE5m bit to 1, and then set the PMC5.PMC5m bit to 1 (m = 0 to 5).
Set the RTPMn register.
Set the RTPCn.EXTRn, RTPCn.BYTEn, and RTPCn.RTPEGn bits.
selected real-time output trigger.
2. Even if the RTBHn and RTBLn registers are written when the RTPOEn bit = 1, data is not transferred to
Note 2
real-time output latches nH and nL, respectively.
real-time output latches nH and nL.
.
CHAPTER 12 REAL-TIME OUTPUT FUNCTION (RTO)
Note 1
.
Page 422 of 892

Related parts for UPD70F3744GJ-GAE-AX