ST7FLITE39F2U6 STMicroelectronics, ST7FLITE39F2U6 Datasheet - Page 119

IC MCU 8BIT 8K FLASH 20QFN

ST7FLITE39F2U6

Manufacturer Part Number
ST7FLITE39F2U6
Description
IC MCU 8BIT 8K FLASH 20QFN
Manufacturer
STMicroelectronics
Series
ST7r
Datasheet

Specifications of ST7FLITE39F2U6

Core Processor
ST7
Core Size
8-Bit
Speed
16MHz
Connectivity
LINSCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
15
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-QFN
For Use With
497-8406 - BOARD STF20NM50FD/STF7LITE39BF2497-8403 - BOARD DEMO STCC08 AC SW DETECTOR497-6398 - BOARD EVAL ST7FLITE39/STM1403497-5858 - EVAL BOARD PLAYBACK ST7FLITE497-5514 - EVAL BOARD THERMO CONTROL REFRIG497-5049 - KIT STARTER RAISONANCE ST7FLITE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5635

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7FLITE39F2U6
Manufacturer:
ST
0
LINSCI™ SERIAL COMMUNICATION INTERFACE (LIN Mode) (cont’d)
LIN HEADER LENGTH REGISTER (LHLR)
Read Only
Reset Value: 0000 0000 (00h).
Note: In LIN Slave mode when LASE = 1 or LHDM
= 1, the LHLR register is accessible at the address
of the SCIERPR register.
Otherwise this register is always read as 00h.
Bits 7:0 = LHL[7:0] LIN Header Length.
This is a read-only register, which is updated by
hardware if one of the following conditions occurs:
- After each break detection, it is loaded with
“FFh”.
- If a timeout occurs on T
00h.
- After every successful LIN Header reception (at
the same time than the setting of LHDF bit), it is
loaded with a value (LHL) which gives access to
the number of bit times of the LIN header length
(T
below:
LHL Coding:
T
LHL(7:2) represents the mantissa of (57 - T
ER
LHL(1:0) represents the fraction (57 - T
LHL7
HEADER_MAX
LHL[7:2]
HEADER
7
)
3Ah
3Bh
3Eh
3Fh
39h
0h
1h
...
...
LHL6
). The coding of this value is explained
LHL5
(57 -
= 57
Mantissa
T
HEADER
56
57
58
62
63
LHL4
...
...
0
1
HEADER
LHL3
)
LHL2
, it is loaded with
Never Occurs
Never Occurs
(
Initial value
T
Mantissa
HEADER
LHL1
HEADER
57
56
...
...
1
0
HEAD-
)
LHL0
0
)
Example of LHL coding:
Example 1: LHL = 33h = 001100 11b
LHL(7:3) = 1100b = 12d
LHL(1:0) = 11b = 3d
This leads to:
Mantissa (57 - T
Fraction (57 - T
Therefore:
(57 - T
and T
Example 2:
57 - T
LHL(1:0) = rounded(4*0.21d) = 1d
LHL(7:2) = Mantissa (36.21d) = 36d = 24h
Therefore LHL(7:0) = 10010001 = 91h
Example 3:
57 - T
LHL(1:0) = rounded(4*0.90d) = 4d
The carry must be propagated to the matissa:
LHL(7:2) = Mantissa (36.90d) + 1 = 37d =
Therefore LHL(7:0) = 10110000 = A0h
LHL[1:0]
HEADER
HEADER
HEADER
0h
1h
2h
3h
HEADER
= 44.25d
= 36.21d
= 36.90d
) = 12.75d
HEADER
HEADER
Fraction (57 -
) = 3/4 = 0.75
) = 12d
1/4
1/2
3/4
0
ST7LITE3xF2
T
HEADER
119/173
)

Related parts for ST7FLITE39F2U6