E3X-DA14V Omron, E3X-DA14V Datasheet - Page 16

DIGTL NPN NANO CONN READY MDL

E3X-DA14V

Manufacturer Part Number
E3X-DA14V
Description
DIGTL NPN NANO CONN READY MDL
Manufacturer
Omron
Series
E3X-DA-Nr
Datasheet

Specifications of E3X-DA14V

Amplifier Type
Water Resistant
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA14V
I/O Circuit Diagrams
NPN Output
Note: With E3X-DA@TW models, only channel 1 is output when set for area sensing operation.
Sensor I/O Connectors for Models with M8 Connectors
E3X-DA11-N
E3X-DAB11-N
E3X-DAG11-N
E3X-DAH11-N
E3X-DA11V
E3X-DA6
E3X-DAB6
E3X-DAG6
E3X-DAH6
E3X-DA14V
E3X-DA21-N
E3X-DA7
E3X-DA11TW
E3X-DA6TW
3
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. (Channel 2 is always OFF.)
Model
4
2
1
1
2
3
4
http://www.ia.omron.com/
Light-ON
Light-ON
Light-ON
Dark-ON
Dark-ON
Dark-ON
Opera-
mode
tion
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
CH1/
CH2
CH1/
CH2
No incident light
No incident light
No incident light
No incident light
Incident light
Incident light
Incident light
No incident light
No incident light
Incident light
Incident light
Incident light
Timing charts
Operate
Operate
Operate
Operate
Operate
Operate
Reset
Reset
Reset
Reset
Reset
Reset
(Between brown and black)
(Between brown and black)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
(Between brown and black)
OFF
OFF
(Between brown and black)
ON
ON
(Between brown and black)
ON
ON
ON
ON
(Between brown and black)
OFF
OFF
ON
ON
ON
ON
ON
ON
Wire colors
T
T
T
T
T
T
Brown
White
Blue
Black
Mode selec-
tor switch
(LIGHT ON)
(LIGHT ON)
(LIGHT ON)
(DARK ON)
(DARK ON)
(DARK ON)
D-ON
D-ON
D-ON
L-ON
L-ON
L-ON
Note: Pin 2 is not used.
Classifi-
cation
DC
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
* Load resistance: 10 kΩ min.
Display
Display
Display
Operation
indicator
(orange)
Wire colors
• Connector Pin Arrangement
Brown
White
Black
Blue
Note: Pin 2 is not used.
(M-8 Connector only)
Photo-
electric
Sensor
main
circuit
Photo-
electric
Sensor
main
circuit
Photo-
electric
Sensor
main
circuit
Operation indicator (orange)
Operation indicator (orange)
Operation indicator (orange)
Connection
pin No.
Output circuit
1
2
3
4
47 Ω
1
Power supply (0 V)
2
Power supply (+V)
1
4
3
4
Orange
Brown
Black
Blue
3
Orange
Application
Brown
Black
Blue
Brown
Black
Blue
Monitor
1 to 5 V
E3X-DA-N
output
Control output 1
Control output 2
Control output
Control output
Output
Load
Load
Load
---
Load
Load
*
12 to
24 VDC
12 to
24 VDC
12 to
24 VDC
16

Related parts for E3X-DA14V