E3X-DA14V Omron, E3X-DA14V Datasheet - Page 8

DIGTL NPN NANO CONN READY MDL

E3X-DA14V

Manufacturer Part Number
E3X-DA14V
Description
DIGTL NPN NANO CONN READY MDL
Manufacturer
Omron
Series
E3X-DA-Nr
Datasheet

Specifications of E3X-DA14V

Amplifier Type
Water Resistant
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA14V
Digital Fiber Amplifiers with Differential Outputs (E3X-DA11D/E3X-DA6D)
Characteristics of Applicable Fiber Units
Through-beam Fiber Units
*1. These values are for sensing objects that are moving.
*2. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
*3. The values given in the above table are those that can be detected at a digital value of 1,000 in each sensing area.
Reflective Fiber Units
*1. Sensing distances are given for white paper.
*2. These values are for sensing objects that are moving.
*3. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
Differences Compared with E3X-DA-N Amplifier
Fiber Unit
E32-T11R
E32-T21R
E32-T16WR
E32-T16PR
Fiber Unit
E32-D11R
E32-D21R
Item
Current consumption
Con-
trol
output
Detection mode
Response time
Func-
tions
Indicators
temperature. (The value is for sensing objects that are moving.)
temperature. (The value is for sensing objects that are moving.)
Sensitivity selection
Sensitivity selection
ON/OFF output
Timer functions
APC
Zero-reset
Initial reset
Sensitivity se-
lection
Teaching level
11-level setting
11-level setting
NPN output
Response
Response
http://www.ia.omron.com/
Type
time
time
For other information, refer to the instruction manual supplied with the product.
Sensing distance (mm) (The figures in parentheses apply when using the 39-F1 Lens Unit.)
240 (1680)
50
580
380
80
13
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load current: 50 mA max., (Residual voltage: 1 V max. for NPN/PNP output)
Open collector
Switchable between Light ON (ON at edge detection) and Dark ON (OFF at edge detection)
Switchable between single edge and double edge detection mode
Single edge: Can be set to 270 μs, 500 μs, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, or 200 ms.
Double edge: Can be set to 570 μs, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms or 400 ms.
Light ON: OFF-delay timer, Dark ON: ON-delay timer
0 to 5 s (1 to 20 ms: 1-ms units, 20 to 200 ms: 5-ms units, 200 ms to 1 s: 100 ms, 1 to 5 s: 1-s units)
Yes
Yes (Negative values can be displayed.)
Yes (Settings can be returned to defaults.)
Yes (HIGH/LOW)
One-point teaching level can be varied from 1% to 50% in increments of 1%
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital detection level display
(red)
270 or
570 μs
270 or
570 μs
1
1
90
15
280 (1960)
60
690
450
0.5 or 1 ms
0.5 or 1 ms
HIGH
HIGH
E3X-DA11D
2
2
Pre-wired
Differential-output Models (Edge-detection Models)
370 (2590)
80
910
600
120
20
1 to 200 ms
or
2 to 400 ms
Sensing distance (mm) *1
1 to 200 ms
2 to 400 ms
or
3 to 11
3-11
140 (980)
30
350
230
45
7
270 or
570 μs
270 or
570 μs
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
1
180 (1260)
40
450
290
60
10
0.5 or 1 ms
0.5 or 1 ms
LOW
LOW
2
2
Wire-saving connector
80
13
240 (1680)
50
580
380
E3X-DA6D
1 to 200 ms
or
2 to 400 ms
1 to 200 ms
or
2 to 400 ms
3 to 11
3-11
E3X-DA-N
150 × 150
(0.01 dia.)
25 × 25 (0.01 dia.)
1 dia. (0.01 dia.)
(0.3 dia.) *1
(0.2 dia.) *2
Standard object
Standard object
(min. sensing
(min. sensing
object *3:
object *2:
opaque)
opaque)
(mm) *1
(mm) *2
8

Related parts for E3X-DA14V