MCF5282CVM80 Freescale Semiconductor, MCF5282CVM80 Datasheet - Page 179

IC MPU 512K 80MHZ 256-MAPBGA

MCF5282CVM80

Manufacturer Part Number
MCF5282CVM80
Description
IC MPU 512K 80MHZ 256-MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5282CVM80

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
150
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Controller Family/series
ColdFire
Ram Memory Size
64KB
Embedded Interface Type
CAN, I2C, SPI, UART
No. Of Pwm Channels
8
Digital Ic Case Style
MAPBGA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282CVM80
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
MCF5282CVM80
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Company:
Part Number:
MCF5282CVM80
Quantity:
4
Part Number:
MCF5282CVM80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Freescale Semiconductor
Bit(s)
7
6
5
4
3
PLLMODE
PLLREF
PLLSEL
LOCKS
Name
LOCK
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
Clock mode bit. The PLLMODE bit is configured at reset and reflects the clock mode
as shown in
1 PLL clock mode
0 External clock mode
PLL select. Configured at reset and reflects the PLL mode as shown in
1 Normal PLL mode
0 1:1 PLL mode
PLL reference. Configured at reset and reflects the PLL reference source in normal
PLL mode as shown in
1 Crystal clock reference
0 External clock reference
Sticky indication of PLL lock status.
1 No unintentional PLL loss of lock since last system reset or MFD change
0 PLL loss of lock since last system reset or MFD change or currently not locked due
The lock detect function sets the LOCKS bit when the PLL achieves lock after:
When the PLL loses lock, LOCKS is cleared. When the PLL relocks, LOCKS remains
cleared until one of the two listed events occurs.
In stop mode, if the PLL is intentionally disabled, then the LOCKS bit reflects the value
prior to entering stop mode. However, if FWKUP is set, then LOCKS is cleared until
the PLL regains lock. Once lock is regained, the LOCKS bit reflects the value prior to
entering stop mode. Furthermore, reading the LOCKS bit at the same time that the
PLL loses lock does not return the current loss of lock condition.
In external clock mode, LOCKS remains cleared after reset. In normal PLL mode and
1:1 PLL mode, LOCKS is set after reset.
Set when the PLL is locked. PLL lock occurs when the synthesized frequency is within
approximately 0.75 percent of the programmed frequency. The PLL loses lock when a
frequency deviation of greater than approximately 1.5 percent occurs. Reading the
LOCK flag at the same time that the PLL loses lock or acquires lock does not return
the current condition of the PLL. The power-on reset circuit uses the LOCK bit as a
condition for releasing reset.
If operating in external clock mode, LOCK remains cleared after reset.
1 PLL locked
0 PLL not locked
• A system reset
• A write to SYNCR that changes the MFD[2:0] bits
to exit from STOP with FWKUP set
Table 9-5. SYNSR Field Descriptions
Table
9-6.
Table
9-6.
Description
Table
9-6.
Clock Module
9-9

Related parts for MCF5282CVM80