CB-OWSPA311GI-01 ConnectBlue, CB-OWSPA311GI-01 Datasheet - Page 53

KIT START OEM WIRELESS LAN RS232

CB-OWSPA311GI-01

Manufacturer Part Number
CB-OWSPA311GI-01
Description
KIT START OEM WIRELESS LAN RS232
Manufacturer
ConnectBlue
Series
OEM Serial Port Adapter™r
Type
Bluetoothr
Datasheet

Specifications of CB-OWSPA311GI-01

Frequency
2.4GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
809-1018
AT*AMSIT Serial Interface Type
AT*AMET Escape Sequence Timing Settings
Responses
<CR><LF>*AMRS<baud_rate>,
<data_bits>,
<stop_bits>,
<parity>,
<flow_control><CR><LF>OK<CR><LF>
<CR><LF>OK<CR><LF>
<CR><LF>ERROR<CR><LF>
Syntax
AT*AMSIT=<type>,<store><CR>
AT*AMET?
Parameters
type
store
Responses
<CR><LF>*AMSIT:<type><CR><LF>OK<CR><LF>
<CR><LF>OK<CR><LF>
<CR><LF>ERROR<CR><LF>
Syntax
AT*AMET=<min_time_before>,
<min_time_after>,<store><CR>
AT*AMET?
Note: If you do not set one of the predefined baud rates the OWSPA311g will try to
use the value you set. It calculates a “true baud rate” that it can use, taking into ac-
count the UART clock. If the original value that you tried to set is within 2% of this
“true baud rate”, the module will return OK. Otherwise it will return ERROR and no
baud rate change will take place after reboot.
Type
Integer
Integer
Description
The serial interface type. Possible values:
1 = RS232 (default)
2 = RS422
3 = RS485
0 = Do not store
1 = Store (will store between reboots)
Description
Write the serial interface type.
Description
Write the escape sequence timing settings.
For an escape sequence to be valid, a period of no data activity is
required before and after the escape sequence. This command reads
the minimum time of no data activity required before and after the es-
cape sequence.
Read the serial interface type.
Read the escape sequence timing settings.
Description
Successful read response
Successful response
Error response
Version 1.6.6 - 2009-11
Description
Successful read response
Successful response
Error response
53