MF0MOU2101DA4,118 NXP Semiconductors, MF0MOU2101DA4,118 Datasheet - Page 8

no-image

MF0MOU2101DA4,118

Manufacturer Part Number
MF0MOU2101DA4,118
Description
IC MIFARE ULTRALIGHT FCP PLLMC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of MF0MOU2101DA4,118

Rf Type
Read / Write
Frequency
13.56MHz
Features
ISO14443A / Mifare
Package / Case
PLLMC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935287579118
NXP Semiconductors
MF0ICU2_SDS_32
Product short data sheet
PUBLIC
7.5.1 REQA
7.5.2 WUPA
7.5.3 ANTICOLLISION and SELECT of cascade level 1
7.5.4 ANTICOLLISION and SELECT of cascade level 2
7.5.5 READ
7.5.6 HALT
7.5.7 WRITE
7.5 Command set
The ATQA and SAK are identical as for MF0ICU1 (see
specification MIFARE
3 “MIFARE ISO/IEC 14443 PICC
The MF0ICU2 comprises the following command set:
The MF0ICU2 accepts the REQA command in Idle state only. The response is the 2-byte
ATQA. REQA and ATQA are implemented fully according to ISO/IEC14443-3.
The MF0ICU2 accepts the WUPA command in the Idle and Halt state only. The response
is the 2-byte ATQA. WUPA is implemented fully according to ISO/IEC14443-3.
The ANTICOLLISION and SELECT commands are based on the same command code.
They differ only in the Parameter byte. This byte is per definition 70h in case of SELECT.
The MF0ICU2 accepts these commands in the Ready1 state only. The response is part 1
of the UID.
The ANTICOLLISION and SELECT commands are based on the same command code.
They differ only in the parameter byte. This byte is per definition 70h in case of SELECT.
The MF0ICU2 accepts these commands in the Ready2 state only. The response is part 2
of the UID.
The READ command needs the page address as a parameter. Only addresses 00h to
2Bh are decoded. For higher addresses the MF0ICU2 returns a NAK. The MF0ICU2
responds to the READ command by sending 16 bytes starting from the page address
defined in the command (e.g. if ADR is ‘03h‘ pages 03h, 04h, 05h, 06h are returned). If
ADR is ‘2Bh’, the contents of pages 2Bh, 00h, 01h and 02h is returned). This is also
applied by configuring the authentication address.
The HALT command is used to set already processed MF0ICU2 devices into a different
waiting state (Halt instead of Idle), which allows a simple separation between devices
whose UIDs are already known (as they have already passed the anticollision procedure)
and devices that have not yet been identified by their UIDs.
The WRITE command is used to program the lock bytes in page 02h, the OTP bytes in
page 03h or the data bytes in pages 04h to 05h. A WRITE command is performed
page-wise, programming 4 bytes in a page.
Ultralight”). For information on ISO 14443 card activation, see
Rev. 3 — 19 May 2009
171432
Selection”.
Ref. 7 “MF0ICU1 Functional
MIFARE Ultralight C
MF0ICU2
© NXP B.V. 2009. All rights reserved.
8 of 15
Ref.

Related parts for MF0MOU2101DA4,118