XR17V354IB176-F Exar Corporation, XR17V354IB176-F Datasheet - Page 46

IC UART PCIE 256B DUAL 176FPBGA

XR17V354IB176-F

Manufacturer Part Number
XR17V354IB176-F
Description
IC UART PCIE 256B DUAL 176FPBGA
Manufacturer
Exar Corporation
Datasheet

Specifications of XR17V354IB176-F

Number Of Channels
4, QUART
Package / Case
176-LFBGA
Features
*
Fifo's
256 Byte
Protocol
RS485
Voltage - Supply
3.3V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
25 Mbps
Supply Current
120 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
No. Of Channels
4
Uart Features
Tx/Rx FIFO Counters
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
BGA
No. Of Pins
176
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR17V354IB176-F
Manufacturer:
EXAR
Quantity:
500
Part Number:
XR17V354IB176-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XR17V354IB176-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR17V354
HIGH PERFORMANCE QUAD PCI-EXPRESS UART
SEE”RECEIVER” ON PAGE 44.
SEE”TRANSMITTER” ON PAGE 42.
DLM[7:0], DLL[7:0] and DLD[3:0]
The Baud Rate Generator (BRG) generates the data rate for the transmitter and receiver. The rate is
programmed through registers DLM, DLL and DLD which are only accessible when LCR bit [7] is set to logic 1.
Refer to
details.
DLD[7]: RS-485 Polarity
DLD[6]: Multi-drop Mode
DLD[5]: XON/XOFF Parity Check
DLD[4]: Fast IR Mode
The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status
and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR) and also
encoded in INT (INT0-INT3) register in the Device Configuration Registers.
When the receive FIFO (FCR bit [0] = logic 1) and receive interrupts (IER bit [0] = logic 1) are enabled, the
RHR interrupts (see ISR bits [4:3]) status will reflect the following:
A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed
B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register
C. The receive data ready bit (LSR bit [0]) is set as soon as a character is transferred from the shift register to
4.0 UART CONFIGURATION REGISTERS
4.1
4.2
4.3
4.4
4.4.1
Logic 0 = The Auto RS-485 Half-duplex direction control pin will be HIGH for TX and LOW for RX.
Logic 1 = The Auto RS-485 Half-duplex direction control pin will be LOW for TX and HIGH for RX.
Logic 0 = Normal mode.
Logic 1 = Enable Multi-drop mode.
Logic 0 = XON/XOFF characters are valid flow control characters even if they have parity errors.
Logic 1 = XON/XOFF characters are not valid flow control characters if they have parity errors.
Logic 0 = If IR mode is enabled, IR pulsewidth will be 3/16th of bit time.
Logic 1 = If IR mode is enabled, IR pulsewidth will be 1/4th of bit time.
trigger level. It will be cleared when the FIFO drops below the programmed trigger level.
status bit and the interrupt will be cleared when the FIFO drops below the trigger level.
the receive FIFO. It is reset when the FIFO is empty.
Receive Holding Register (RHR) - Read only
Transmit Holding Register (THR) - Write only
Baud Rate Generator Divisors (DLM, DLL and DLD)
Interrupt Enable Register (IER) - Read/Write
“Section 3.1, Programmable Baud Rate Generator with Fractional Divisor” on page 32
IER versus Receive FIFO Interrupt Mode Operation
46
REV. 1.0.1
for more