CD22M3494E Intersil, CD22M3494E Datasheet - Page 7

no-image

CD22M3494E

Manufacturer Part Number
CD22M3494E
Description
Analog Crosspoint Switch IC
Manufacturer
Intersil
Datasheet

Specifications of CD22M3494E

Peak Reflow Compatible (260 C)
No
Ic Function
Analog Crosspoint Switch
Leaded Process Compatible
No
Mounting Type
Through Hole
Package / Case
40-DIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CD22M3494E
Quantity:
138
Part Number:
CD22M3494E
Manufacturer:
ST
0
Part Number:
CD22M3494E
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
CD22M3494EZ
Manufacturer:
Intersil
Quantity:
57
Part Number:
CD22M3494EZ
Manufacturer:
INTERSIL
Quantity:
20 000
To make a connection (close switch) between any two points, specify an “X” address, a “Y” address, set “DATA” high, and switch
“STROBE” from low to high. To break a connection, follow this same procedure with “DATA” low.
Typical Performance Curve
Pin Descriptions
POWER SUPPLIES
ADDRESS
CONTROL
AX0 - AX3
AY0 - AY2
SYMBOL
STROBE
RESET
DATA
V
V
V
CS
DD
SS
EE
5, 22, 23 and 4
24, 25 and 2
40 LD PDIP
PIN NO.
40
16
20
38
18
36
3
Example:
To connect switch X3 to switch Y4:
To connect switch X6 to switch Y7:
To break connection from X3 to Y4:
7
MQ
44
18
22
40
70
60
50
40
30
20
10
0
5, 24, 25 and 4
44 LD PLCC
26, 27 and 2
r
V
ON
EE
PIN NO.
-40°C
-8
vs V
= -6V, V
85°C
25°C
42
20
3
IN
-6
AT -55°C, 25°C AND 85°C
SS
SQ
44
17
22
39
= 0V, V
CD22M3494
-4
DD
-2
= 6V
V
Positive Supply.
Negative Supply (Digital).
Negative Supply (Analog).
X Address Lines. These pins select one of the 16 rows of switches. See
the Truth Table for the valid addresses.
Y Address Lines. These pins select one of the 8 columns of switches. See
the Truth Table for the valid addresses.
DATA Input determines the state of the addressed switch. A high or one
will close the switch. A low or zero will open the switch.
STROBE Input enables the action defined by the DATA and ADDRESS
Inputs. A low or zero results in no action. The ADDRESS Input must be
stable before the STROBE Input goes to the active high level. The DATA
Input must be stable on the failing edge of the STROBE.
MASTER RESET. A high or one on this line opens all switches.
CHIP SELECT. Device is selected when CS is at a high level, allows the
crosspoint array to be cascaded for matrix expansion.
IN
0
(V)
DATA
2
1
1
0
4
AX3
0
1
0
6
X ADDRESS
AX2
8
0
0
0
DESCRIPTION
AX1
1
0
1
AX0
1
0
1
AY2
1
1
1
Y ADDRESS
AY1
January 16, 2006
0
1
0
FN2793.7
AY0
0
1
0

Related parts for CD22M3494E