Photoelectric Sensor

S18SN6FF50Q

Manufacturer Part NumberS18SN6FF50Q
DescriptionPhotoelectric Sensor
ManufacturerBANNER ENGINEERING
TypeFixed Field
S18SN6FF50Q datasheets
 


Specifications of S18SN6FF50Q

Output Current150mASensor OutputNPN
Supply Voltage Range Dc10V To 30VSensing Range Max25mm
Leaded Process CompatibleNoPeak Reflow Compatible (260 C)No
Sensor InputLaserPrimary TypePhotoelectric
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Page 31
32
Page 32
33
Page 33
34
Page 34
35
Page 35
36
Page 36
37
Page 37
38
Page 38
39
Page 39
40
Page 40
41
42
Page 36/42

Download datasheet (8Mb)Embed
PrevNext
T18 Series
Compact Sensors
Supply Voltage and Current
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current):
Opposed Mode Emitters: 25 mA
Polarized Retroreflective: 30 mA
Diffuse: 25 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Solid-state complementary (SPDT) dc switch; NPN (current sinking) or PNP (current sourcing), depending on model.
The Dark Operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon
hookup to the power supply.
Output Rating
150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA;
Off-state leakage current: less than 1 mA at 30V dc;
On-state saturation voltage: less than 1V at 10 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF; Polarized Retroreflective, Non-polarized Retroreflective,
Fixed-field and Diffuse: 3 milliseconds ON/OFF
NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time
Adjustments
T18 Series infrared non-polarized retroreflective and diffuse mode models (only) have a single-turn rear-panel
SENSITIVITY control for adjustment of system gain (turn clockwise to increase)
Repeatability
Opposed: 375 microseconds; Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field and
Diffuse: 750 microseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow
Green ON steady: power to sensor is ON
Green flashing: output is overloaded (dc models only)
Yellow ON steady: Light Operate (LO) output is energized
Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Operating Conditions
Temperature: -40° to +70° C
Vibration and
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double
Mechanical Shock
amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Certifications
Hookup Diagrams
Emitters: DC03 (p. 476)
100
bannerengineering.com
More information online at
T18 DC Specifications
Opposed Mode Receivers: 20 mA
Non-polarized Retroreflective: 25 mA
Fixed-field: 35 mA
Relative humidity: 90% at 50° C (non-condensing)
R
NPN Models: DC07 (p. 477)
PNP Models: DC08 (p. 477)