E5GN-C1LD-C AC/DC24 Omron, E5GN-C1LD-C AC/DC24 Datasheet - Page 10

no-image

E5GN-C1LD-C AC/DC24

Manufacturer Part Number
E5GN-C1LD-C AC/DC24
Description
CONTROLLER, TEMP, 24AC/DC
Manufacturer
Omron
Datasheet

Specifications of E5GN-C1LD-C AC/DC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Svhc
No SVHC (15-Dec-2010)
Accuracy
±0.3 Of PV
Approval Bodies
CE, CSA
Approval Category
UL Recognised
Colour
Black
External
RoHS Compliant
Input Ranges
Thermocouple/Platinum Resistance Thermometer (Universal Inputs)
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
Models with Analog Inputs
Shaded settings are the default settings.
Setting
number
Input specification
Setting range
Setting number
Name
Input
Type
−100.0
−200.0
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
Input Type
−200 −199.9
850
0
Platinum resistance
Pt100
500.0
thermometer
1
100.0
0.0
2
−199.9
500.0
JPt100
3
100.0
Usable in the following ranges by scaling:
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999
0
4 to 20 mA
0.0
4
1300
−200
5
K
Current
500.0
−20.0 −100 −20.0
6
1
0 to 20 mA
850
7
J
400.0
8
−200 −199.9 −200
400
9
2
T
1 to 5 V
400.0
10
600
11
E
Thermocouple
−100
850
12
3
L
Voltage
0 to 5 V
−200 −199.9 −200
400
13
U
400.0
14
4
1300
15
0 to 10 V
N
1700 1700
16
R
0
17
S
0
1800
100
18
B
2300
24
W
0
1300
PL
25
II
0
10 to
70°C
Infrared temperature
19
90
0
60 to
120
120
20
°C
sensor
0
115
165
165
°C
21
to
0
140
260
260
22
°C
to
0
E5GN
Usable
in the
following
ranges
by
scaling:
−1999 to
9999 or
−199.9
to 999.9
Analog
50 mV
input
0 to
23
10

Related parts for E5GN-C1LD-C AC/DC24