E5GN-C1LD-C AC/DC24 Omron, E5GN-C1LD-C AC/DC24 Datasheet - Page 8

no-image

E5GN-C1LD-C AC/DC24

Manufacturer Part Number
E5GN-C1LD-C AC/DC24
Description
CONTROLLER, TEMP, 24AC/DC
Manufacturer
Omron
Datasheet

Specifications of E5GN-C1LD-C AC/DC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Svhc
No SVHC (15-Dec-2010)
Accuracy
±0.3 Of PV
Approval Bodies
CE, CSA
Approval Category
UL Recognised
Colour
Black
External
RoHS Compliant
Models with Analog Inputs
Models with One Control Output and a 100 to 240-VAC Power Supply
Note: Models with analog inputs do not display the temperature unit.
*1. If heating/cooling control mode is used, an auxiliary output is used as a control output for the cooling side. The number of auxiliary outputs that
*2. A current control output can be used as the transfer output. In that case, an auxiliary output is used as the control output. (This is not possible
Models with One Control Output and a 24-VAC/VDC Power Supply
*1. If heating/cooling control mode is used, an auxiliary output is used as a control output for the cooling side. The number of auxiliary outputs that
*2. A current control output can be used as the transfer output. In that case, an auxiliary output is used as the control output. (This is not possible
Accessories (Order Separately)
USB-Serial Conversion Cable
Waterproof Packing
Note: The Waterproof Packing is included with the Controller only for models with screw terminal blocks.
Current Transformers (CTs)
CX-Thermo Support Software
Note: The E5GN is supported by CX-Thermo version 4.2 and higher.
Black
Black
Case color
Case color
can be used will decrease by one. Also, the signal for the control output for the cooling side will be a relay output.
for models without an auxiliary output.) The control output will be a relay output. The number of auxiliary outputs that can be used will decrease
by one.
can be used will decrease by one. Also, the signal for the control output for the cooling side will be a relay output.
for models without an auxiliary output.) The control output will be a relay output. The number of auxiliary outputs that can be used will decrease
by one.
Hole diameter
12.0 dia.
5.8 dia.
Current
output
Current
output
Control
Control
output
output
Standard or
heating/
cooling
Standard or
heating/
cooling
EST2-2C-MV4
mode *1
mode *1
E58-CIFQ1
Control
Control
Y92S-32
Model
Model
Model
1
1
auxiliary
auxiliary
outputs
outputs
No. of
No. of
E54-CT1
E54-CT3
Model
Detection of
---
Detection of
---
SSR failure,
overcurrent
SSR failure,
overcurrent
and heater
and heater
burnout,
burnout,
heater
heater
No. of event
---
No. of event
---
inputs
inputs
Transfer
output using
control
output
Transfer
output using
control
output
output *2
output *2
Transfer
Transfer
---
---
Communi
Communi
cations
cations
Thermocou-
---
Thermocou-
---
ple input
ple input
Previous model
Previous model
---
---
Resistance
Resistance
thermome-
thermome-
ter input
ter input
E5GN-C1L-C
E5GN-C1LD-
C
New model
New model
E5GN
8

Related parts for E5GN-C1LD-C AC/DC24