E5GN-C1LD-C AC/DC24 Omron, E5GN-C1LD-C AC/DC24 Datasheet - Page 2

no-image

E5GN-C1LD-C AC/DC24

Manufacturer Part Number
E5GN-C1LD-C AC/DC24
Description
CONTROLLER, TEMP, 24AC/DC
Manufacturer
Omron
Datasheet

Specifications of E5GN-C1LD-C AC/DC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Svhc
No SVHC (15-Dec-2010)
Accuracy
±0.3 Of PV
Approval Bodies
CE, CSA
Approval Category
UL Recognised
Colour
Black
External
RoHS Compliant
Lineup
Note: Models with one control output and one or two auxiliary outputs can be used for heating/cooling control.
Model Number Structure
Model Number Legend
Controllers
1. Control Output 1
2. Auxiliary Outputs
3. Option
Note: Models cannot be made for all combinations of options that are possible in the model number legend. Confirm model availability in Ordering
* Auxiliary outputs are relay outputs that can be used to output alarms or processing results.
E5GN-@@@@@-@-@-@
R: Relay output
Q: Voltage output (for driving SSR)
C: Linear current output
Blank: None
1: One output
2: Two outputs
Blank: None
01: RS-232C communications
03: RS-485 communications
B: Two event inputs
H: Heater burnout/Heater short/Heater overcurrent detection
E5GN
Basic Type
(CT1)
Information before ordering.
1 2
3 4 5
6
7
Screw terminal block
8
Screwless clamp
terminal block
Temperature input
Temperature input
Analog input
Analog input
4. Input Type
5. Power Supply Voltage
6. Terminal Type
7. Case Color
8. Communications Protocol
T: Universal thermocouple/platinum resistance thermometer input
L: Analog current/voltage input
Blank: 100 to 240 VAC
D: 24 VAC/VDC
Blank: Models with screw terminal block
C: Models with screwless clamp terminal block
Blank: Black
Blank: None
FLK: CompoWay/F communications
1 control output
1 control output
1 control output
1 control output
0, 1, or 2 auxiliary
outputs
0, 1, or 2 auxiliary
outputs
0, 1, or 2 auxiliary
outputs
0, 1, or 2 auxiliary
outputs
E5GN