H3DS-AL Omron, H3DS-AL Datasheet - Page 4

Multifunction Timer

H3DS-AL

Manufacturer Part Number
H3DS-AL
Description
Multifunction Timer
Manufacturer
Omron
Datasheet

Specifications of H3DS-AL

Time Range
0.1 To 1.2 Sec, 10 - 120 Hr
Supply Voltage Ac, Min
24VAC
Supply Voltage Dc, Max
48VDC
Supply Voltage Dc, Min
24VDC
Length/height, External
80mm
Supply Voltage Ac, Max
230VAC
External Width
17.5mm
External Depth
73mm
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
H3DS
Note: For reference:
Accuracy of operating time
Setting error
Signal input time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Impulse withstand voltage
Noise immunity
Static immunity
Life expectancy
EMC
Case color
Enclosure rating
Weight
Characteristics
A maximum current of 0.15 A can be switched at 125 VDC (cos =1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
50 ms min.
100 M min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts:
2,000 VAC for 1 min.
Between control output terminals and operating circuit: 2,000 VAC for 1 min.
Between contacts not located next to each other: 1,000 VAC for 1 min.
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 100 m/s
Destruction: 1,000 m/s
3 kV (between power terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 1.5 kV
Malfunction: 4 kV
Destruction: 8 kV
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI):
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS):
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance:
Immunity Burst:
Light gray (5Y7/1)
IP30 (Terminal block: IP20)
100 g
1% max. of FS ( 1% 10 ms max. at 1.2-s range)
10% 50 ms max. of FS
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)
2% max. of FS ( 2% 10 ms max. at 1.2-s range)
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
(see note)
2
3 times each in 6 directions
2
3 times each in 6 directions
EN50081-1
EN55022 class B (equivalent to EN55011 class B)
EN55022 class B (equivalent to EN55011 class B)
EN61000-3-2
EN50082-2
EN61000-4-2:4 kV contact discharge (level 2)
ENV50140:
ENV50204:
ENV50141:
EN61000-4-4:2 kV power line (level 3)
8 kV air discharge (level 3)
10 V/m (80 MHz to 1 GHz) (level 3)
10 V/m (900 5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV I/O signal line (level 4)