R88A-CRWA005C Omron, R88A-CRWA005C Datasheet - Page 34

no-image

R88A-CRWA005C

Manufacturer Part Number
R88A-CRWA005C
Description
ENCODER CABLE 5m
Manufacturer
Omron
Datasheet

Specifications of R88A-CRWA005C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
G5+
Specifications
Ordering Information
G5+ Inverter
I-26
Instantaneous overcurrent
Fuse protection
Overload
Overvoltage
Undervoltage
Momentary power loss
Fin overheat
Stall prevention
Ground fault
Power charge indication
Environmental conditions
Location
Ambient temperature
Storage temperature
Humidity
Elevation
Wiring distance
Vibration
Other functions
Input signals
Multi-function inputs
Output signals
Multi-function outputs
Standard functions
Flux vector inverter with constant
torque control
Inverters
Description
For complete specifications and additional models:
(Continued)
Motor coasts to a stop at approximately 200% rated output current
Motor coasts to a stop at blown fuse
Motor coasts to a stop after one minute at 150% rated output current
Motor coasts to a stop if converter output voltage exceeds 1,050 VDC at 600 V input
Motor coasts to a stop if converter output voltage drops to 546 VDC or below at 600 V input
Immediate stop after 15ms or longer power loss (setting mode before shipment)
Thermostat
Stall prevention during accel/decel and constant speed operation
Provided by electronic circuit (overcurrent level)
Charge led stays ON until bus voltage drops below 50 VDC
Indoor (Protected from corrosive gases and dust)
+14 to 104°F (-10 to 40°C) for NEMA 1 type
+14 to 113°F (-10 to 45°C) for Open Chassis Type
-4 to 140°F (-20 to 60°C)
95% RH (Non-condensing)
1,000 m (3,281 feet) or below
328 ft (100 m) or less between inverter and motor
9.8 m/s
3 Analog Inputs available (0 to 10 V, -10 to +10 V, 4 to 20 mA)
8 Digital Inputs with 6 programmable for functions such as: 3 wire sequencing (2 wire is standard), multi-step
speed operation, fault reset, external fault (NO or NC), jog, accel/decel time select, MOP function, speed search
command, Local/Remote selection, motor 1 or 2 selection, PID disable, PID reset, trim increase or decrease,
fast stop, analog signal selection, and many others
2 Analog Outputs (0 to 10 V) with 25 different settable functions
4 Digital Outputs (Form C fault contacts plus 3 programmable outputs [1 form A, 2 open collector]).
Programmable Output functions available are: run signal, zero speed, frequency agree (2), frequency detection
(4), torque level detection (2), timer output, at current/torque limit, regenerating, minor or major fault, DB
overheat, loss of reference, and many others.
Settable for V/Hz, open loop vector, or closed loop vector, DC injection braking, PID control, zero servo mode,
energy saving mode, 4 accel/decel times with S-curve, 8 preset speeds, slip and torque compensation, 3 jump
frequencies, stall prevention, auto restart, and many other standard features.
NEMA 1
Open chassis
2
(1G) less than 20 Hz, up to 1.96 m/s
Enclosure
2 HP, 3.5 A, 575 VAC
3 HP, 4.1 A, 575 VAC
5 HP, 6.3 A, 575 VAC
7.5 HP, 9.8A, 575 VAC
10 HP, 12.5 A, 575 VAC
15 HP, 17.0 A, 575 VAC
20 HP, 22.0 A, 575 VAC
25 HP, 27.0 A, 575 VAC
30 HP, 32.0 A, 575 VAC
40 HP, 41.0 A, 575 VAC
50 HP, 52.0 A, 575 VAC
60 HP, 62.0 A, 575 VAC
75 HP, 77 A, 575 VAC
100 HP, 99 A, 575 VAC
120 HP, 130 A, 575 VAC
150 HP, 172 A, 575 VAC
200 HP, 200 A, 575 VAC
2
U.S. www.omron.com/oei Canada www.omron.ca
(0.2G) at 20 to 50 Hz
Rating
G5M-51P5-N1
G5M-52P2-N1
G5M-53P7-N1
G5M-55P5-N1
G5M-57P5-N1
G5M-5011-N1
G5M-5015-N1
G5M-5018-N1
G5M-5022-N1
G5M-5030-N1
G5M-5037-N1
G5M-5045-N1
G5M-5055-N1
G5M-5075-N1
G5M-5090-N0
G5M-5110-N0
G5M-5160-N0
Model