R88A-CRWA005C Omron, R88A-CRWA005C Datasheet - Page 36

no-image

R88A-CRWA005C

Manufacturer Part Number
R88A-CRWA005C
Description
ENCODER CABLE 5m
Manufacturer
Omron
Datasheet

Specifications of R88A-CRWA005C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
P5+
Powerful 600V Variable Torque Inverter for
Building Automation
• Energy savings software helps reduce power consumption
• Built-in PID function allows feedback loop
• Highly programmable with 116 parameters
• UL listed electronic thermal overload that eliminates external
• Speed search function restarts a coasting motor without
• Multi-function Inputs (5) & Outputs (3) for increased flexibility
• 5 preset speeds (4 speeds + jog) allows multi-step operation
• Stall prevention/Current limit prevent overcurrent trips and
• Momentary power loss ride-through Continue the operation,
• Critical frequency lockouts (2) to avoid mechanical
• Alphanumeric digital operator makes programming easier to
• Communications cards for MetaSys N2, Apogee, and
• Common control board across all models
• 3rd generation IGBT output section
• Terminals for optional DC link reactor (from 2HP / 600V up to
• Built-in braking IGBT (from 2HP / 600V up to 30 HP / 600V)
• Built-in RS-232C port for direct connection to programming
Specifications
I-28
Power Supply
600V rated input voltage &
frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Control Characteristics
Control method
Frequency control range
Frequency accuracy
Frequency setting resolution
Output frequency resolution
Overload capacity
Frequency setting signal
Accel/Decel
Braking torque
Protective Functions
Motor overload protection
devices
stopping it, after a power loss
motor stall
after recovery from a momentary power loss
resonance (as in cooling towers)
understand
Echelon LONworks building automation protocols. Use
optional communication card Modbus RTU to control up to
31 Drives
20 HP / 600V)
tools
Inverters
P5+
Inverters
For complete specifications and additional models:
3-phase, 500/575/600 VAC, 50/60 Hz
-15% of 500 VAC, +10% of 600 VAC
±5%
Sine Wave PWM
0.1 to 400 Hz
Digital Operator Reference: 0.01%
Analog Reference: 0.1%
Digital Operator Reference: 0.01 Hz
Analog Reference: 0.06 Hz/60 Hz
0.01 Hz
120% rated output current for one minute (150% for constant torque rating)
0 to +10 V (20 kΩ), 4 to 20 mA (250 Ω)
0.01 to 3600.0 sec (Accel/Decel time setting independently; 0.1sec)
Approximately 20%
UL recognized internal electronic thermal overload relay (I
Canada Only
U.S. www.omron.com/oei Canada www.omron.ca
2
t)
G089A