R88A-CRWA005C Omron, R88A-CRWA005C Datasheet - Page 37

no-image

R88A-CRWA005C

Manufacturer Part Number
R88A-CRWA005C
Description
ENCODER CABLE 5m
Manufacturer
Omron
Datasheet

Specifications of R88A-CRWA005C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
P5+
Specifications
Ordering Information
P5+ Inverter
Manuals
For complete specifications and additional models:
Instantaneous overcurrent
Fuse protection
Overload
Overvoltage
Undervoltage
Momentary power loss
Fin overheat
Stall prevention
Ground fault
Power charge indication
Environmental Conditions
Location
Ambient temperature
Storage temperature
Humidity
Elevation
Vibration
Wiring distance
Other Functions
Analog inputs
Multi-function digital inputs
Analog outputs
Multi-function digital outputs
Standard functions
Variable torque inverter
User’s manual
Inverters
Description
Item
User’s manual
(Continued)
NEMA 1
Open chassis
Motor coasts to a stop at approximately 180% rated output current
Motor coasts to a stop at blown fuse
Motor coasts to a stop after one minute at 120% rated output current (150% for constant torque)
Motor coasts to a stop if converter output exceeds 1,050 VDC at 600 VAC input
Motor coasts to a stop if converter output voltage drops below 546 VDC
Immediate stop after 15 ms or longer power loss
(Continuous system operation during power loss less than 2 seconds is equipped as standard)
Thermistor – OH1, OH2
Stall prevention during accel/decel and constant speed operation
Provided by electronic circuit
Charge LED stays on until bus voltage drops below 50 VDC
Indoor (Protected from corrosive gases and dust)
+14 to 104°F (-10 to 40°C) for NEMA 1 type (not frozen)
+14 to 113° F (-10 to 45° C) for Open Chassis type
-4 to 140°F (-20 to 60°C)
95% RH (non-condensing)
1000 m (3281 feet) or below
9.8 m/s
328 ft (100 m) or less between inverter and motor
2 analog inputs available (0-10 V, 4-20 mA)
6 Digital Inputs with 5 programmable for functions such as: 3 wire sequencing (2 wire is standard), multi-step
speed operation, fault reset, external fault (NO or NC), jog, accel/decel time select, speed search command,
Local/Remote selection, PID disable, PID reset, fast stop, serial communication select, timer start, parameter
lockout, and many others.
1 Analog Output (0-10 V) settable as output frequency, output current, output KW, or DC bus voltage.
2 Programmable Digital Outputs (1 form C and 1 form A), Programmable functions available are: run signal,
fault, at speed, frequency detection (2), overtorque detection (NO or NC), timer output, loss of reference or PID
feedback, and many others.
DC injection braking, PID control, Energy Saving mode, 2 accel/decel times with S-curve, 4 preset speeds,
selectable for constant or variable torque, 2 jump frequencies, stall prevention, auto restart, power-loss ride
through, and many other standard features.
Enclosure
2
(1G) less than 20 Hz, up to 1.96 m/s
2 to 3 HP, 3.9 A, 600 VAC
5.0 HP, 7.0 A, 600 VAC
7.5/10 HP, 11 A, 600 VAC
15 HP, 19 A, 600 VAC
20 HP, 25 A, 600 VAC
25 HP, 30 A, 600 VAC
30 HP, 36 A, 600 VAC
40 HP, 46 A, 600 VAC
50 HP, 58 A, 600 VAC
60 HP, 69 A, 600 VAC
75 HP, 86 A, 600 VAC
100 HP, 111 A, 600 VAC
200 HP, 192 A, 600 VAC
125/150 HP, 145 A, 600 VAC
U.S. www.omron.com/oei Canada www.omron.ca
Description
2
(0.2G) at 20 to 50 Hz
Rating
P5M-51P5-N1
P5M-53P7-N1
P5M-55P5-N1
P5M-5011-N1
P5M-5015-N1
P5M-5018-N1
P5M-5022-N1
P5M-5030-N1
P5M-5037-N1
P5M-5045-N1
P5M-5055-N1
P5M-5075-N1
P5M-5090-N0
P5M-5110-N0
IM-P5
Model
Model
I-29

Related parts for R88A-CRWA005C